6
-
Initial Installation & Operation
General
The filter assembly is packed on a wooden platform with all its parts installed.
Installation (Figure 3)
1. Take the filter assembly out of the wood platform.
2. Install the filter assembly to the inlet line and outlet line.
3. Connect a drainpipe to the hydraulic flushing valve outlet opening (at least 80 mm or
3” diameter and no longer then 10m). Confirm that water runs freely out of the
drainpipe.
4. Position the control panel in such a way as to be protected against humidity
and solar radiation.
5. Connect the control panel to the power source.
6. Check that all connections are properly secured.
7. Check that all bolts and nuts on filter periphery are properly tightened and
secured.
Figure 3: Initial Filter Installation