Automated Logic LGE Technical Instructions Download Page 1

Automated Logic Corporation

1150 Roberts Blvd.

Kennesaw, GA 30144

• 

770/429-3000

770/429-3001 Fax

• 

www.automatedlogic.com

• 

Copyright 1999 Automated Logic Corporation. All rights reserved. Automated Logic, the

Automated Logic logo, SuperVision, Eikon, and Alert are registered trademarks of Automated Logic Corporation.
InterOp is a trademark of Automated Logic Corporation. BACnet

®

is a registered trademark of ASHRAE. All other brand

and product names are trademarked by their respective companies.

Technical Instructions

LGE

Using the LGE 2
Specifications 3
Mounting 3
Addressing 3

LGnet Addressing 3
IP Addressing 4

Wiring 5

Power Wiring 5
Communications Wiring 5

Transferring Memory 6
Troubleshooting 6

Communicating with the Workstation 6
Formatting the Module 7
LEDs 8
Protection 8
Production Date 8

Summary of Contents for LGE

Page 1: ...Corporation InterOp is a trademark of Automated Logic Corporation BACnet is a registered trademark of ASHRAE All other brand and product names are trademarked by their respective companies Technical I...

Page 2: ...ion The LGE uses the CEM module driver for more information see the CEM Module Driver document on the Automated Logic website at www automatedlogic com CAUTION Changes or modifications to this unit no...

Page 3: ...net Console Port 1 and Ethernet communications errors running and power Memory 1 MB flash 1 MB RAM Protection Built in surge and transient protection circuitry Battery 7 year lithium BR2325 battery pr...

Page 4: ...d the local network segment Assigned When the IP Addr DIP switch is set to Assigned you must set the above parameters on the CEM Parameter page Use the following procedure to set the IP address when u...

Page 5: ...s the module from being powered up before the proper voltage is verified 2 Make sure the 24VAC power source is off 3 Connect the power wires to the module s power terminals labeled Ground and 24VAC se...

Page 6: ...erVision v3 0 click Tools Troubleshooting Module Status To view the module status report in SuperVision v2 6b press the Esc key type MO module address 15 and press Enter 3 Transfer memory to the modul...

Page 7: ...l the Error LED flashes three times in sync with the Run LED 4 Release the Format button 5 Transfer memory to the module Refer to Transferring Memory on page 6 Figure 5 Wiring Diagrams Figure 6 Using...

Page 8: ...ion Refer to the SuperVision User s Guide for more information about the Module Status report A sticker on the back of the module also shows the date the module was manufactured The first three charac...

Reviews: