4
、
Slow speed function B4(Red DIP switch 4)
Red Dip Switch4 in ON positionwith slow speed function, it will auto learn the travelling,
and do not need manually setting. When power on for the first time, press remote control ,motor will be
move to the limit slowly, and then press the counter-direction, motor will
be fast and then slow speed to the limit. Repeat this steps 2 times with remote control, after hear
DI sound, travel setting is finished. Do not stop the motor during the process of setting.
(Note:It can adjust the slow speed thrust by MT knob if motor thrust not enough. Motor
slow position is fixed, about 20cm. )
5
、
Max.force startingfunction B5 (Red DIP switch 5)
Red Dip Switch 5 in ON position with max.force starting. If the door is heavy and can not start by soft start, it
can turn on Red Dip switch 5 to on, make the door starting, but this will increase the noise from door starting.
6
、
Function setting B6 (Red DIP switch 6)
RED Dip Switch 6 in ON position ,can set the function of the remote single key control and auto closing time
and so on ,it needs to turn to OFF after finished the setting.
7
、
Resistance rebound function B7 (Red DIP switch 7)
RED Dip Switch 7 in ON position with resistance rebound function.
Functional optimal adjustment scheme:Set the resistance potentiometer to minimum, then gradually
increase clockwise to find a point of appropriate force. The force cant too small and too big.
8
、
Motor direction conversionB8 (Red DIP switch 8)
When the gate traveling direction and limit are in correspondingposition , the gate is not in limit position and
do not have movement, just turn red dip switch 8 to change the direction, others do not change.
Loop Detector
Three states of Loop detector input:
1
、
When the gate is closing, there is loop detector signals input. The gate will reverse to the opening position.
Then the gate will close after 2 seconds delay
2
、
When the gate is opening, there is loop detector signals input, the motor continues to running, the gate
will close after 2 seconds delay when the opening travel is over.
3
、
When the motor touched the limit, and the gate will close after loop detector signal input two seconds
Usage of IR sensor