AUTOGEN BC-2B Quick Manual Download Page 2

Original Language Version

Also refer to the vehicle manufacturer’s handbook. IF IN ANY DOUBT CONSULT A QUALIFIED

ELECTRICIAN.

Ensure the charger is in good condition before use. If in any doubt

DO NOT

use the unit, contact your AUTOGEN stockist.

Familiarise yourself with the application, limitations as well as the potential hazards of the charger.

DO NOT

smoke or allow a spark or flame in the vicinity of battery or engine.

1.4.

CHARGING SAFETY INSTRUCTIONS

Use the starter/charger in the upright position only and ensure it is placed on a stable surface which will adequately support its weight.

Ensure the charger is disconnected from the mains supply before attaching/detaching the power clamps to/from the battery.

Keep tools and other items away from the engine and ensure you can see the battery and working parts of engine clearly.

Ensure the output of the charger is the same voltage as the battery.

If battery has caps to access the battery fluid, remove the caps and check the fluid level before connecting the power clamps.

If necessary top-up the battery with distilled water by referring to the battery manufacturer’s instructions (Apply the personal safety

precautions described in part 1.3).

If the charger receives a sharp knock or blow the unit must be checked by a qualified service agent before use.

If the battery terminals are corroded or dirty clean them before attaching the power clamps.

Keep children and unauthorized persons away from the working area.

DO NOT

dis-assemble the charger for any reason. The charger must only be checked by qualified servicepersonnel.

DO NOT

try to charge a non-rechargeable battery.

DO NOT

try to charge battery if battery fluid is frozen.

WARNING!

To prevent the risk of sparking, short circuit and possible explosion

DO NOT

drop metal tools in the battery area, or allow

them to touch the battery terminals.

DO NOT

allow power clamps to touch each other or to make contact with any metallic part of the vehicle.

DO NOT

cross connect power leads from charger to battery. Ensure positive (+/RED) is connected to positive and negative (-/BLACK) is

connected to negative.

DO NOT

pull the cables or clamps from the battery terminals.

DO NOT

use the charger outdoors, in damp, or wet places.

DO NOT

operate within the vicinity of flammable liquids or gases.

DO NOT

use charger inside vehicle or inside engine compartment.

Ensure there is effective ventilation to prevent a build-up of explosive gases, and

DO NOT

cover or obstruct charger ventilation louvers.

DO NOT

exceed the intended use of the charger.

WARNING! DO NOT

charge batteries of different capacities or discharge levels simultaneously.

WARNING!

If a fuse blows, ensure it is replaced with an identical fuse type and rating. Use only AUTOGEN genuine parts.

When not in use, store the charger carefully in a safe, dry, and child-safe location.

This appliance can be used by children aged from 8 years and above to the person with reduced physical, sensory or mental capabilities or lack

of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the

hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

2. INTRODUCTION

Compact 6/12V dual bank battery charger perfect for automobile, motorcycle and marine workshops. Suitable for charging a variety of batteries.

Charger reacts continuously to battery condition and delivers any required charge rate. Two bank charger outputting 2 x 5A depending on the

condition and the charge rate of each battery. constantly regulated voltage patterns allow the battery to be recharged fully and safely without fear of

overcharging. Compatible with all AGM, Gel and VRLA flooded batteries commonly found in everything from automotive and farm equipment to

motorcycles, ATV’s, golf buggies and personal watercraft.

3. SPECIFICATION

MODEL NO.

BC-2B

INPUT

100-120V AC, 50Hz

OUTPUT VOLTAGE

6V & 12V

CHARGE CURRENT

5A

BATTERY TYPES

6V & 12V lead acid batteries (WET, MF, AGM and GEL)

CHARGING VOLTAGE

14.4V ± 0.25V (for 12V battery) or 7.2V ± 0.20V (for 6V battery)

AMBIENT TEMPERATURE

-10°C to +40°C

HOUSING PROTECTION

IP65

4. OPERATION

4.1.

PREPARATION

It is important to correctly prepare for charging. Ensure you follow Section 1 safety regulations carefully. Check that the capacity of the

battery is compatible with the charger output.

4.1.1.

Follow any vehicle manufacturer’s instructions regarding battery charging. Note special instructions for in-vehicle charging.

4.1.2.

Check polarity of battery posts. A positive (pos, p, +) battery post may have a larger diameter than a negative (neg, n, -) post;

4.1.3.

Connect the battery lead plastic plug to the charger / maintainer plastic plug, see fig.1.

4.2.

BATTERY CHARGING

4.2.1.

Follow the battery manufacturer’s recommendations for battery cell caps

during charging. Loosen cell caps if applicable.

4.2.2.

Open all battery compartments and ventilate for at least 15 minutes before

plugging into the mains supply.

4.2.3.

Connect the battery lead terminal rings or alligator clips directly to the

corresponding battery posts.

4.2.4.

Position the RED terminal ring or alligator clip on the POSITIVE post

connector.

4.2.5.

Position the BLACK terminal ring or alligator clip on the NEGATIVE post

connector. Make sure all battery connections are tight and clean.

Reviews: