background image

 

 

 

CHARGING STATION

 

«

TRAVEL CHARGER

»

 

 

 

User manual

Summary of Contents for Travel Charger

Page 1: ...CHARGING STATION TRAVEL CHARGER User manual ...

Page 2: ...lly compiled at the time of publication Under no circumstances will compliance with the information in this Manual relieve the user of his responsibility to comply with all applicable codes safety standards or wiring regulation The developer cannot be held liable for any direct or indirect damages resulting from the use or operation of the electrical circuits of the equipment or software described...

Page 3: ...FICATIONS 9 2 PACKAGE 9 3 MARKING 10 4 INSTALLATION 11 4 1 OPERATING LIMITATIONS 11 4 2 STATION INSTALLATION 11 4 3 STATION CONNECTING 12 5 OPERATION 13 5 1 OPERATING MODES AND ELECTRIC VEHICLE CHARGING PROCESS 13 5 2 CONNECTING THE VEHICLE 14 5 3 SAFETY MEASURE 14 6 MAINTENANCE 15 7 TROUBLESHOOTING 16 8 STORAGE 17 9 TRANSPORTATION 17 10 DISPOSAL 17 11 FAT CERTIFICATE 18 11 1 ADDRESS OF MANUFACTUR...

Page 4: ...nnel and fully understood Important safety instructions in this manual are indicated by symbols These safety instructions must be strictly followed You should always pay attention to them and follow the safety requirements to avoid accidents personal injury or property damage WARNING Risk of injury or death This symbol indicates instructions that must be followed to avoid injury trauma or death AT...

Page 5: ...ftware described in this manual The manufacturer is not responsible for damage and or malfunctions caused by non compliance with the instructions in this manual The manufacturer will not be liable for any personal injury or material damage whether indirect or special consequential loss of business profits business interruption or loss of business information resulting from the use of the equipment...

Page 6: ...ween the station and the electric vehicle The control and protection functions operate continuously in the system The station is available in several modifications All modifications are equipped with one fixed cables with CHAdeMO CCS Type 1 CCS Type 2 GB T DC connectors 1 2 FUNCTIONAL POSSIBILITIES Mount Wall Floor Online monitoring of device operation Possibility to adjust the charge current Poss...

Page 7: ...cal protection IK10 Case protection class IP54 Operating temperature 35 C to 50 C Relative humidity no more than 95 without moisture condensation Net mass kg 48 Charging station dimensions H W D mm Wall mounting Floor mounting 660 360 215 400 660 890 360 270 Communication and protocols 2G GSM GPRS Class 12 Quad band 850 900 1800 1900MГц 3G 4G LTE LTE Cat 1 LTE FDD B1 B3 B7 B8 B20 B28A GSM B3 B8 RF...

Page 8: ...socket voltage 500 V Cable length 5 5 m Charging connector CCS Type 1 Maximum power per socket 30 kW 40 kW Maximum current per socket 100 A 120 A Maximum socket voltage 500 V 1000 V Cable length 5 5 m Charging connector CCS Type 2 Maximum power per socket 30 kW 40 kW Maximum current per socket 100 A 120 A Maximum socket voltage 500 V 1000 V Cable length 5 5 m ...

Page 9: ...nding on the connector type and mounting type 2 PACKAGE EV charging station Travel Charger can be supplied in various package depending on the installation method Wall mounting EV charging station Travel Charger 1 Adapter CEE plug 5 pin 63 A Type 2 male plug 1 User manual 1 Mounting bracket 1 Anchor screw M8 4 Floor mounting EV charging station Travel Charger 1 Adapter CEE plug 5 pin 63 A Type 2 m...

Page 10: ...r wall mounting Travel Charge V2 Figure 1а Station external view and station dimensions for floor mounting 3 MARKING The nameplate is located on the charging station enclosure side panel The nameplate specifies information such as the model serial number and basic technical specifications ...

Page 11: ...sult with a licensed electrician contractor and trained installation expert to insure compliance with local building codes safety standards and wiring regulations 4 2 STATION INSTALLATION Make sure the installation site has relevant GSM or 4G LTE cellular coverage Cellular repeaters may be required to ensure good signal strength in underground garages or other enclosed parking lots It is recommend...

Page 12: ... does not require any special adjustment or tuning before it is put into operation ATTENTION DO NOT SWITCH ON THE CHARGER WITHOUT A CONNECTED GROUNDING Non compliance with this requirement may result in energizing the charger body electric shock damage to the service personnel and consumers as well as in a failure of the charger To connect the charging station to the electric circuit it is necessa...

Page 13: ...sion After the supply voltage is applied the station display shows information about the software version and the serial number of the modem In case of malfunctions in the operation of the charging station you must inform the serial number of the modem to the service center for diagnostics and restoration of work In standby mode the display shows information about the status of the connectors In c...

Page 14: ...tation there is an emergency stop button When the emergency stop button is pressed the electrical circuit that powers the vehicle s battery is automatically disconnected The message EMO PRESSED appears on the display To continue the operation of the station the emergency stop button must be manually returned to its original state turn the button counterclockwise ...

Page 15: ...pulling connections Filter replacement Identification of defective parts assemblies their repair and replacement Preventive inspection of the charger should be carried out at least once every 3 months To do this the charger must be disconnected from live circuits and its housing contacts and vents must be thoroughly cleaned of dust and dirt and the quality of wire fastening must be checked Screws ...

Page 16: ...owerful Charging cable or connector fault Depreciation careless handling of equipment De energize the device Contact to Customer Service to replace charging cable or connector The charging station display does not work there is no information on the station display No input voltage Find out the reason for the lack of voltage Restore power supply Circuit breaker s tripped off Bring circuit breaker ...

Page 17: ...RANSPORTATION The charging station can be transported by all means of transport During transportation take all necessary measures to ensure protection from atmospheric precipitation mechanical damages and movements Protect the charger from damage during transportation with straps and inserts and leave sufficient clearance between the station and other transported items Shipping temperature range 0...

Page 18: ...er Station purchased from manufacturer or one of its authorized distributors Subject to the exclusions set forth below manufacturer warrants that the Station will be free from defects for a period of two 2 year after the date of delivery manufacturer s warehouse Warranty Period unless manufacturer and its direct customer Customer explicitly agree otherwise in writing Customer may transfer the Warr...

Page 19: ...quipment damaged as a result of incorrect electrical mechanical connection misuse or Station usage beyond its intended purpose modification or changes in the design of the product without written manufacturer approval incorrect installation assembly disassembly or relocation of the Station unless performed by manufacturer or authorized service personnel maintenance and repair of product performed ...

Page 20: ...ion or the service will not exceed the price of this station ADDITIONAL INFORMATION Owner is responsible for the proper installation and maintenance of the Station This Limited Product Warranty is not transferable by the Station s Owner to anyone else PC AE FACTORY reserves the right to update any information illustrations sheets specifications and diagrams contained in these Manual at any time wi...

Reviews: