![AutoAqua Smart ATO Lite G2 Manual Download Page 3](http://html.mh-extra.com/html/autoaqua/smart-ato-lite-g2/smart-ato-lite-g2_manual_3020976003.webp)
2
Installation
Caution : Risk of Injury from Strong Magnets
*Please set the sensor away from the water outlet to avoid bubble
interference.
1. Mount the square dual sensor on the tank/sump with the magnet,
and adjust the lower sensor to the desired water level.
*
2.
Connect one tube with the pump. Plug the siphon break into tubes,
keep it higher than the water level of the reservoir, and set up the
water tube with the universal holder.
3.
Connect both of the DC pump and power adapter with the controller
and then connect power.
Optical Level Sensor
Tank/Sump
Reservoir
DC Re ll Pump
Power
Siphon break must be higher than the
water level in the reservoir.
Air In :
Siphon break allows air in to break
the siphon when the pump turns off.
Water Out :
Water drops out of the
hole are normal when the pump is on.
Direction
Air In
Water Out