44
The Control Module will not turn
on due to a completely discharged
Control Module battery
On the Contol Module (CM), hold the power button for at least 5 seconds.
If the CM still does not turn on, place the CM into the Load Module. Place the entire unit into the
wall mounted charging station, and look for the Load Module's LED to go to a solid, or blnking
red. Let the CM & LM charge for at least 3 hours.
The Load Module LED is off.
Remove the CM, and press the LM button for 1 second, and release. The LED should turn
red for about a second, then turn green. If the LED still does not turn on, the LM battery
may need to be charged. Reinstall the CM onto the LM, and place the entire unti into the
wall mounted charging station. The LED on the LM should turn on, to a solid red while
charging. Let the unit charge for at least 3 hours.
To power the Control Module
on while the Control Module is
charging
Press & hold the power button until the Samsung Splash screen appears. A few seconds
later, a battery outline will appear on the screen. When it does, press and hold the power
button while the battery outline is visible. Once the battery outline goes away, release the
button. The Samsung Splash screen will appear, and the CM will continue to boot.
The Control Module will not
make a Bluetooth connection to
the Load Module
Please see BCT-460NAV does not read battery temperature, earlier in this Troubleshooting
guide.
TROUBLESHOOTING
Replacement Parts & Accessories
AC-31 Group 31 Battery Adapters
AC-90 Charging Station
AC-94 20’ External Voltage Leads
AC-95 45’ External Voltage Leads (These were not originally included with the BCT-460NAV, but are available if long voltage drop
leads are needed).
AC-98 Starter Adapters
AC-102 Alternator Adapters
AC-105 Large Replacement Leads and Clamps
AC-107 Adapter Kit with Storage Bag (Includes the AC-31, AC-98, and AC-102 adapters)
AC-108NAV Replacement Control Module
AC-111 Replacement Wall Charger (Plugs directly into the Load Module)
AC-112 Replacement Wall Charger for the AC-90 Charging Station
AC-113 Replacement Load Module Battery