Digital Inspection Operations
Operations
131
2.
Screw the thread part of the accessory over the imager head to fix the
accessory.
17.1.1 Technical Specifications
Table 17- 1
Technical Specifications
Item
Description
Optimal
Viewing Distance
1" to 14" (2.54cm to 35.56cm) with 8.5mm
diameter imager head
3/8" to 12" (0.95cm to 30cm) with 5.5mm
diameter imager head
Image Capture
JPG images (640x480) AVI videos (320 x 240)
Operating Temperature
Main Unit: 0°C to 55°C (ambient)
Cable: -10°C to 70°C
Storage Temperature
-20°C to 75°C (ambient)
Waterproof
Imager head and cable to 1m
Weight
0.3kg with 8.5mm diameter imager head
0.2kg with 5.5mm diameter imager head
17.2 Operations
Before performing the Digital Inspection application, the Imager Head Cable
must be connected to the Display Tablet through the USB port. Install the
correct imager head accessories for use in the appropriate application.
NOTE
: When in operation, the imager head cable can be bent into a certain
shape. This may help you operate the cable into confined areas.