Dragonfish Series Maintenance Manual
2.
Confirm if there is any error information of automatic
inspection by running self-inspection process via APP;
Power
1.
Unlock ground trial run with an idle speed manually after
self-inspection, to observe motor rotation and confirm
rotation direction of motor;
List of Flight Tests
Types
Emphasis
Trial flight test
1.
Confirm the application of test environment, which must be
free of strong electromagnetic interference, personal and
property safety hazard and no-fly area or restricted area; the
flight zone is legal;
2.
Carry out prior-flight inspection;
3.
Unlock manually after passing self-inspection for hovering at
a height of 5 m. Push joysticks at all directions to observe the
status of aircraft.
4.
Control the landing of aircraft;
5.
Carry out self-inspection again and then unlock it manually;
transfer modal after climbing to a height of 70m;
6.
Carry out spiral climb and descending under fixed wing
modal to observe the status of aircraft;
7.
Switch to multi-rotor modal manually and then control
aircraft landing;
8.
Make verification by setting automatic task based on field
operation demands.
Inspection after landing
1.
Inspect if the appearance of paddle, motor and body is normal
and free of abnormalities such as cracking, loosening, rupture,
etc.;
2.
Inspect if the motor temperature is normal;
3.
Inspect clearance of steering engine.