5 | Technical data
EN
Operating manual Heidi Back 2.0
16
6
Specification mg/m³ for heated filter method (in compliance with Annexe III, number 4, letter a, sec-
tion i, point 1) or g/kg for measurement in dilution tunnel (in compliance with Annexe III, number 4, let-
ter a, section i, point 2 and 3.)
7
Specifications must be made here for the preferred fuel only.
5.2
General specifications
Technical data
Basic appliance
Height [mm]
1074
Width [mm]
620
Depth [mm]
405
Firebox height [mm]
355
Firebox width [mm]
418
Combustion chamber depth [mm]
270
Baking compartment height [mm]
178
Baking compartment width [mm]
346
Baking compartment depth [mm]
283
Weight [kg]
167.5
Weight [kg] steel/ceramic/soapstone
- / - / -
Weight, HMS [kg]
68.5
Flue pipe outlet, diameter [mm]
130
Nominal heat efficiency [kW] as per EN test EN 13240
7
Heat output, minimum [kW]
3.5
Maximum heat output [kW]
9
Space heating capacity, at least (depending on the building insulation) [m³]
82
Maximum room-heating capacity (depending on the building insulation) [m³]
210
Minimum distance from non-flammable materials [mm]
50
Max. amount of fuel to be deposited [kg] (log)
1.7
5.3
Data for the chimney/flue dimensioning
Exhaust gas values for the multiple occupancy of the chimney (according to DIN 4705 Part 3) or rating of the
chimney (according to DIN 4705 Part 2)
Flue gas mass flow [g/s]
6.41
Flue gas temperature [°C]
262
Minimum feed pressure at nominal heat output [Pa] closed
10
at 0.8 times nominal heat output [Pa]
8
Safety distances a, b, c [mm]
1300 / 200 / 200