5

 

Installation 

5.1

 

Scope of Delivery 

Scope of delivery: 

1.

 

Heat pump WPA 230 ECO 

2.

 

Instructions for installation and use 

3.

 

Levelling feet 

5.2

 

Storage 

The appliance must be stored in a dry and clean place. The allowed storage temperature is between 
10

°

C and 45

°

C, for a short period of time (up to 24 hrs) the temperature can reach up to 55

°

C.   

 

5.3

 

Transport 

During transportation, the heat pump is protected with protective foil and cardboard packaging to 
prevent damage such as indentations and scratches.  If necessary, the heat pump can be additionally 
protected to avoid mechanical damages. After transportation, the device must be kept in the upright 
position for at least 2 hours so that the distributed oil collects again in the compressor.    
 

 

CAUTION 

 

The appliance is too heavy for manual transportation. Such transportation can 
lead to personal injuries and damages to the device. All responsibility for 
possible damages is assumed by the buyer.  

 

 

CAUTION 

 

Never place the heat pump in horizontal position.  
 

5.4

 

Place of Installation 

The heat pump should in no case be installed in a place, where there are harmful substances present 
in the air (stables, storage rooms for hazardous substances, outdoors, etc.). The minimum ceiling 
height must be at least 2100 mm and the minimum room size must be 20 m

3

. The construction of the 

device enables the heat pump to exploit the warmth of the ambient air or to supply the inlet air from 
the neighbouring rooms or from the outside via air duct system. The heat pump enables the 
following types of ventilation, depending on the design of the piping system:  
 

Summary of Contents for WPA 233 E-LF

Page 1: ...ANG Instructions for Use and Installation Domestic Hot Water Heat Pump WPA 303 E LF These instructions must be handed over to the end user...

Page 2: ...21 Printed in Austria Copyright by Austria Email AG This text is protected by copyright Any use outside limits of the copyright act without the consent of Austria Email AG is illegal and punishable by...

Page 3: ...tions 7 3 1 Safety Advice 7 3 2 Recommendations 7 3 3 Safety Data Sheet Refrigerant R134a 8 3 3 1 Identification 8 3 3 2 Potential Dangers 8 3 3 3 Composition 8 3 3 4 First Aid 8 3 3 5 Fire Fighting M...

Page 4: ...mp Start up 25 6 1 Filling the System with Water 25 6 2 Control prior to Start up 25 6 3 Connection of the Heat Pump to the Power Network 25 6 4 Start up 26 6 5 Heat Pump Operation 26 6 6 Settings 27...

Page 5: ...ompany is also glad to be at your disposal through the Customer Services and Sales Departments for any advice you may require If you intend to hand over this product to a third person make sure that y...

Page 6: ...tria Email AG When ordering spare parts for this device please provide the following product exact title of the product serial number production year All necessary information can be obtained from the...

Page 7: ...for use and maintenance in a suitable dry place near the appliance 2 3 Conformity The CE sign confirms that the appliance is manufactured in compliance with the currently valid directives and standar...

Page 8: ...vision or instruction by the person in charge Children must be supervised to ensure that they do not play with the device During operation the device must not be moved cleaned or mended Before install...

Page 9: ...of health risks Refrigerant vapours are heavier than air Refrigerant can cause displacement of air from a room As a consequence dizziness loss of consciousness or even suffocation may occur Liquefied...

Page 10: ...r of suffocation due to low concentrations of oxygen in the air Evacuate the danger area Stop the leakage Remove all potential sources of ignition heat The room in which the leakage of the refrigerant...

Page 11: ...xceed 500 litres WPA 230 ECO 700 litres WPA 302 ECO While heating tap water the heat pump simultaneously cools down the area where it is installed or from which the air is taken In addition to tap wat...

Page 12: ...mm 700 D mm 780 E mm 900 F mm 1175 G mm 1375 H mm 1422 I mm 1853 1 Cold water connection 1 2 Heating water connection 1 return flow 3 Heating water connection 1 outlet flow 4 Flange 5 Recirculation c...

Page 13: ...of a heat pump is a very efficient way of hot water supply A heat pump consists of a heat pump unit compressor evaporator fan etc and a water heater The housing of the unit is made of a resistant EPP...

Page 14: ...n 2 Condenser 3 Filter dryer 4 Expansion valve 5 Evaporator 6 Fan 7 Expansion valve sensor 8 El heater 9 Mg anode 10 11 El heater safety thermostat 12 Sensor heat pump 13 High pressure switch 14 Heat...

Page 15: ...ter temperature in the water heater The OPTITRONIC regulation is used to monitor the heating of water to the set temperature Depending on the set water temperature the regulation starts or stops the o...

Page 16: ...power for circ pump 300 W COPt EN16147 A15W55 XL 3 0 2 9 Refrigerant R134a 0 9kg Max water temperature 60 C 65 C 75 C Required air flow rate 500 m3 h Protection class IPX1 Ambient air temperature 7 35...

Page 17: ...urs so that the distributed oil collects again in the compressor CAUTION The appliance is too heavy for manual transportation Such transportation can lead to personal injuries and damages to the devic...

Page 18: ...from a neighbouring room and discharged back into the same room Drying of linen Figure 2 Air supply and discharge take place in the room where the HP is installed Figure 3 Air is supplied from a neigh...

Page 19: ...ction must be carried out in accordance with the current national and local regulations which apply to the connection of water heaters Figure below illustrates a correct hydraulic connection of the he...

Page 20: ...ection The distance between the point of air intake and the point of air discharge should not exceed 10 m Frequent change of the air flow direction is regarded as additional air resistance which means...

Page 21: ...densate Discharge The extraction of heat from the air causes the condensation of air humidity in the heat pump Depending on the season and hot water requirements between 1 and 5 litres of condensate p...

Page 22: ...end of the tube a siphon must be made to prevent suction of odours from the drain Routing of the condensate outlet pipe must always provide the water to freely drain from the device It is recommended...

Page 23: ...ated in various ways with different heat generators The primary heat generator is the heat pump however when the heat pump cannot operate on its own it can be connected to the secondary heat generator...

Page 24: ...Austria Email AG 23 V1 0 1 2021...

Page 25: ...TENTION The connection cable can only be plugged into a grounded socket 16 A 230 V a c 1 Compressor 11 Fan capacitor 2 Fan 12 Safety thermostat 3 Display 13 Electrical heater 4 Pressure switch 14 Rela...

Page 26: ...all water pipes in the building When the water is running without any bubbles the system is properly filled and evacuated CAUTION The heat pump must not be in operation if the water tank is empty oth...

Page 27: ...ogramme automatic overheating of water over 60 C every 14 days or in a time period from 1 to 99 days Auto diagnostic programme Identification and display of errors during operation 6 5 Heat Pump Opera...

Page 28: ...RIPTION not illuminated not illuminated P0 Operation of the heat pump is switched off only display of the water temperature in the storage tank is active illuminated not illuminated P1 Heat pump is he...

Page 29: ...n for safety reasons NOTE BY PRESSING THE KEY THE CURRENTLY SELECTER PROGRAMME IS SHOWN this can also be seen from the light indicators see the above table WITH EACH FURTHER PRESSING OF THE KEY WITHIN...

Page 30: ...ectric heater until the set water temperature is reached The active and safety thermostat of the electric element is limited to 65 C Because the temperature sensor is installed under the electric heat...

Page 31: ...y Select parameter L1 and after a few seconds the pre set switch off temperature set to 5 C While the set temperature is displayed it can be freely changed by using the and key from 9 C to 30 C 5 seco...

Page 32: ...ff the heat pump loosen the screws remove the top plastic cover and clean the fins with a vacuum cleaner or blow through them with air Make sure that you do not damage the fins or any other part of th...

Page 33: ...unction of the evaporation temperature sensor First reset the heat pump and check the connection cable of the air sensor If the error occurs again contact the repair service Description of malfunction...

Page 34: ...Austria Email AG 33 V1 0 1 2021 10 Warranty Guarantee and Product Liability...

Page 35: ...Austria Email AG 34 V1 0 1 2021...

Reviews: