© Austria Email AG
16
V1.0 1/2021
5
Installation
5.1
Scope of Delivery
Scope of delivery:
1.
Heat pump WPA 230 ECO
2.
Instructions for installation and use
3.
Levelling feet
5.2
Storage
The appliance must be stored in a dry and clean place. The allowed storage temperature is between
10
°
C and 45
°
C, for a short period of time (up to 24 hrs) the temperature can reach up to 55
°
C.
5.3
Transport
During transportation, the heat pump is protected with protective foil and cardboard packaging to
prevent damage such as indentations and scratches. If necessary, the heat pump can be additionally
protected to avoid mechanical damages. After transportation, the device must be kept in the upright
position for at least 2 hours so that the distributed oil collects again in the compressor.
CAUTION
The appliance is too heavy for manual transportation. Such transportation can
lead to personal injuries and damages to the device. All responsibility for
possible damages is assumed by the buyer.
CAUTION
Never place the heat pump in horizontal position.
5.4
Place of Installation
The heat pump should in no case be installed in a place, where there are harmful substances present
in the air (stables, storage rooms for hazardous substances, outdoors, etc.). The minimum ceiling
height must be at least 2100 mm and the minimum room size must be 20 m
3
. The construction of the
device enables the heat pump to exploit the warmth of the ambient air or to supply the inlet air from
the neighbouring rooms or from the outside via air duct system. The heat pump enables the
following types of ventilation, depending on the design of the piping system: