5.6 Circuit Diagrams

EBH-KDW1 4,0kW

EBH-TDW1 4,0 kW

Heating elements

3 x 1,35 kW / 230 V

3 x 40 Ohm

Circuit in factory configuration

4,0 kW / 3~400V 

200 litres

4 hrs. / 4,0 kW

6 hrs. / 2,7 kW

8 hrs. / 2,0 kW

EBH-KDW1 6,0kW

EBH-TDW1 6,0 kW

Heating elements

3 x 2,0 kW / 400 V

3 x 80 Ohm

Circuit in factory configuration

6,0 kW / 3~400V 

300 litres

4 hrs. / 6,0 kW

6 hrs. / 4,0 kW

8 hrs. / 3,0 kW

Summary of Contents for EBH-KDW

Page 1: ...EBH KDW EBH TDW Operating and Mounting Instructions Please pass on to the user Id Nr 228557 15 ...

Page 2: ...ion Of course our customer service and sales department are readily available to support you in case you need any advice Enjoy the use of your built in electric heater TABLE OF CONTENTS Page Safety instructions 3 1 Function 4 2 Energy Saving 4 3 Operation and Temperature Setting 4 4 Operating Requirements 4 5 Information for Assembly and Installation 5 5 1 General Information for Installation 5 5 ...

Page 3: ...the responsibility for the proper assembly according to the applicable laws standards and guidelines The immersion heater may only be installed in dry freeze protected spaces The data specified on the nameplate immersion heater as well as tank must be observed Prior to the commissioning of the immersion heater the heating rods must be completely sur rounded by water Electrical Connection Only qual...

Page 4: ...ed using day current Due to the hysteresis of the temperature control 7 K and possible radiation losses cooling down of the pipelines the temperature specifications are subject to an accuracy of 10 K 4 OPERATING REQUIREMENTS The built in heating must be used exclusively in accordance with the requirements operating pressure heating time supply voltage etc specified on the rating plate The power co...

Page 5: ...ey resist temperatures of 110 C and any consequential damages are avoided in the event of any malfunction of the temperature control Assembly and installation must be performed exclusively by licensed craftsmen Fitting position The flange must not be longer than max 130 mm so that the thermometer and the heating unit still project into the hot water tank sufficiently The built in heating unit must...

Page 6: ...gle item 4 set desired service water tem perature 6 Do not put into operation until the tank is filled with water The assembly of the heating installation and the initial start up must be performed exclusively by an expert who thereby accepts responsibility for proper implementation and equipping 5 3 Information on Corrosion Protection The built in heater is designed for installation in enamelled ...

Page 7: ...nits for intensive care etc In rooms with bathtubs or showers the device must be installed in accordance with the national laws and regulations e g of ÖVE SEV VDE or DIN VDE 0100 701 The technical connecting requirements TAB of the relevant energy supply company must absolutely be observed A residual current circuit breaker with a tripping current I N 30mA must be connected in series before the el...

Page 8: ...Nr 228557 15 5 6 Circuit Diagrams EBH KDW1 4 0kW EBH TDW1 4 0 kW Heating elements 3 x 1 35 kW 230 V 3 x 40 Ohm Circuit in factory configuration 4 0 kW 3 400V 200 litres 4 hrs 4 0 kW 6 hrs 2 7 kW 8 hrs 2 0 kW ...

Page 9: ...Id Nr 228557 15 9 EBH KDW1 6 0kW EBH TDW1 6 0 kW Heating elements 3 x 2 0 kW 400 V 3 x 80 Ohm Circuit in factory configuration 6 0 kW 3 400V 300 litres 4 hrs 6 0 kW 6 hrs 4 0 kW 8 hrs 3 0 kW ...

Page 10: ...10 Id Nr 228557 15 EBH KDW1 8 0kW EBH TDW1 8 0 kW Heating elements 3 x 2 7 kW 400 V 3 x 60 Ohm Circuit in factory configuration 8 0 kW 3 400V 400 litres 4 hrs 8 0 kW 6 hrs 5 0 kW 8 hrs 4 0 kW ...

Page 11: ...Id Nr 228557 15 11 EBH KDW1 10 0kW EBH TDW1 10 0 kW Heating elements 3 x 3 3 kW 400 V 3 x 48 Ohm Circuit in factory configuration 10 0 kW 3 400V 500 litres 4 hrs 10 0 kW 6 hrs 6 5 kW 8 hrs 5 0 kW ...

Page 12: ...he red LED is lit no corrosion protection is active Corrosion protection is only guaranteed if the green LED lights up continuously Should the red or yellow LED light up or flash please inform Customer Services immediately A conductivity value of the medium of 150 μS cm is necessary for proper functioning of the external current anode The guard circuit shunt resistor must not be damaged or removed...

Page 13: ...h the device improperly carried out repairs Insufficient water conductivity min 150 µs cm operational wear of the magnesium anode wearing part natural formation of boiler scale lack of water fire flood lightning overvoltage power failure or other types of force majeure Use of non original and company external components such as e g heating elements reactive anode thermostat thermometer ribbed tube...

Page 14: ...r dismantled before being inspected by the manufacturer or an appointed expert Any change to the original assembly situation on site will lead to the immediate exclusion of any claims arising from the war ranty guarantee or product liability To prevent misidentification of the water heater during transport it must be marked with a highly visible and legible marking preferably including address and...

Reviews: