background image

1

 Mic/Line 1-4 

Blue indicates signal presence

Pink indicates approaching signal clip

Red indicates signal clip

2

 Stereo 1-4 

Blue indicates signal presence

Pink indicates approaching signal clip

Red indicates signal clip

3

  Page Inputs 1-2

Blue indicates signal

 

presence

Pink indicates approaching signal clip

Red indicates signal clip

4

 Power Indicator 

Blue indicates mains power is present

5

 RS485 Indicator 

Blue indicates remote panels are present, the light 
will fl ash when data is passed across this network

6

 Status Indicator 

Blue indicates the system is running

Red indicates the system is busy or has an error

7

 Network Indicator 

Blue indicates a network device is connected. 
The light will fl ash each time a packet is passed 
across this network

8

 Zone Outputs 

Blue indicates signal presence

Pink indicates approaching signal clip

Red indicates signal clip

PAGE 2

ZONE REVOLUTION QUICKSTART MANUAL

FRONT PANEL

1

4

5

6

7

8

2

3

Summary of Contents for Zone Revolution

Page 1: ...Zone Revolution Quick Start Manual ...

Page 2: ...Notez tous les avertissements 3 Suivez toutes les avertissements 4 N utilisez pas ce produit près de l eau la piscine la plage le lac etc 5 Nettoyez seulement avec une étoffe sèche 6 Ne bloquez aucuns troux de ventilation Installez en accord avec 7 les instructions du manufacturier N installez près aucunes sources de chaleur comme radiateurs registres 8 de chaleur fours ou les autres équipements y...

Page 3: ...RIDE GLOBAL PRESETS 9 CONTROL PANEL OPTIONS 10 DIMENSIONS 11 SPECIFICATIONS 12 WARNING TO PREVENT FIRE OR SHOCK HAZARD DO NOT USE THE PLUG WITH AN EXTENSION CORD RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE TO PREVENT ELECTRICAL SHOCK MATCH WIDE BLADE PLUG T...

Page 4: ...es mains power is present 5 RS485 Indicator Blue indicates remote panels are present the light will flash when data is passed across this network 6 Status Indicator Blue indicates the system is running Red indicates the system is busy or has an error 7 Network Indicator Blue indicates a network device is connected The light will flash each time a packet is passed across this network 8 Zone Outputs...

Page 5: ...m 5 RS485 Ports The RS485 ports allow for the connection of ICON CP control panels using standard pin to pin wiring Use of straight through CAT5 cable is suggested to keep the RS485 line twisted for optimal noise rejection 6 AM Linking Ports The AM Linking ports allow multiple Zone Revolution units to be linked for expansion purposes This feature is for future use 7 Balanced Zone Outputs Balanced ...

Page 6: ...ested that when connecting to the Zone Revolution for the first time that a crossover cable is used straight between the unit and your PC You will then need to change your network adapter to have an IP of 192 168 178 170 with a subnet of 255 255 255 0 Then all you will need to do is open the Zone Rev software and connect Once you have connected for the first time you can set the units IP address o...

Page 7: ...pe in the Old password and then leave the new password box blank a prompt should appear telling you that the password has been removed Advanced Mode Set Up At the base of the advanced mode screen there are four buttons added to the GUI These allow set up of functions relating to the Audio Setup Control Panels Master Override and Presets Audio Setup The Audio Setup page allows the user to control a...

Page 8: ...n when enabled provides priority paging to this input Input EQ Each input has comprehensive EQ functions high and low pass filters high and low shelf and two parametric filters Each EQ can be adjusted in either Q or BW All processing is represented on the EQ frequency response graph on the right hand side of that window You can save processing preset files for each block from the EQ onwards This a...

Page 9: ...ave EQ Each output also offers comprehensive EQ functions These allow a user to configure a low and high shelf and 4 parametric filters Limiter Each output features a fully optioned limiter with stereo link function on stereo zones Delay Each output has a delay for both the left and the right channel It has coarse and also fine control for setting in precise delays The user can also simply type in...

Page 10: ...amed for easy identification Once a name is given to a panel the user can specify its type options are 6 Volume 6 buttons volume or 8 buttons Panel Set Up From the Configure screen the user can set up the zone to be controlled and what parameter the control panel affects PAGE 8 ZONE REVOLUTION QUICKSTART MANUAL ICON CP CONTROL PANELS PANEL SET UP ...

Page 11: ... be typically used for closure The trigger source can be either signal presence or closed contact Once a trigger source has been selected you can configure the Master Override to Mute all Inputs Route Mic Line 4 to all and or Enable Paging Any combination of these settings is permitted When Route Mic Line 4 to all is selected the controls for that channel disappear from the front page so the end u...

Page 12: ...was to fail or be broken it could simply be swapped out with a unit set to the same address All control panels are constantly polling the RS485 network for status This will allow the user to update settings via 3rd party other control panels or the software GUI and have all panels constantly up to date Each RS485 port on the Revolution series allows you to run up to 20 control panels to a maximum ...

Page 13: ...PAGE 11 ZONE REVOLUTION QUICKSTART MANUAL ZONE REVOLUTION DIMENSIONS ICON CP DIMENSIONS ...

Page 14: ...tem Frequency Response 20 20000 Hz THD N 0 003 From Input to Output 1KHz 4dBu Dynamic Range 108 dB Sample Rate 48 kHz Latency 2 1 ms Analog to Analog Processor 2 x Analog Devices Sharc DSP ADSP 21375 32 40 bit floating point Processing Power 2 x 1596 MFLOPS Communications Ethernet 100 Base T Icon Control Panel RS485 500 m Max cable length per port without external power 20 Max number of remote pan...

Page 15: ...PAGE 13 ZONE REVOLUTION QUICKSTART MANUAL NOTES ...

Page 16: ...iries email international australianmonitor com au DISTRIBUTED IN AUSTRALIA AND NEW ZEALAND BY HILLS SVL www hillssvl com au NSW P 02 9647 1411 QLD P 07 3852 1312 ACT P 02 6260 4544 WA P 08 9204 0200 VIC P 03 9890 7477 SA P 08 8408 8300 NZ P 09 415 9426 E nsw hillssvl com au E qld hillssvl com au E act hillssvl com au E wa hillssvl com au E vic hillssvl com au E sa hillssvl com au E sales hillssvl...

Reviews: