AUSTRALIAN MONITOR Synergy SY1200 Specifications Download Page 2

Synergy

Series

Specifications

SY400

Output power 
per channel at 4 ohms

200W

Output power 
per channel at 8 ohms

130W

Output power in bridge 
mode at 8 ohms

400W

Frequency Response

15Hz-80kHz 
+0dB -3dB

Distortion

Better than 0.03%

Input Sensitivity

1Vrms

Voltage Gain

28.3

Slew Rate

>40V/us

Damping Factor

>375:1

Signal to Noise

Better than 97dB

Input Impedance

20kohm

Input clipping

+20dBV

Cooling

Front to Back

Amplifier Indicators

Power, Status(Signal/
Clip), Overload,
Thermal, Fault

Amplifier Controls

Volume, Ground Lift,
Bridge Switch, Limiter

Amplifier Protection

Current Limiting, DC
Protection, mains fuse,
DC rail fuses, Slow
Start, Thermal Cutout

Dimensions

87x482x400

Net weight

10kg

Shipping weight

12kg

Shipping dimensions

210x540x470

SY800

Output power 
per channel at 4 ohms

375W

Output power 
per channel at 8 ohms

235W

Output power in bridge 
mode at 8 ohms

750W

Frequency Response

15Hz-70kHz 
+0dB -3dB

Distortion

Better than 0.03%

Input Sensitivity

1Vrms

Voltage Gain

38.7

Slew Rate

>40V/us

Damping Factor

>430:1

Signal to Noise

Better than 97dB

Input Impedance

20kohm

Input clipping

+20dBV

Cooling

Front to Back

Amplifier Indicators

Power, Status(Signal/
Clip), Overload,
Thermal, Fault

Amplifier Controls

Volume, Ground Lift,
Bridge Switch, Limiter

Amplifier Protection

Current Limiting, DC
Protection, mains fuse,
DC rail fuses, Slow
Start, Thermal Cutout

Dimensions

87x482x400

Net weight

13kg

Shipping weight

15kg

Shipping dimensions

210x540x470

SY1200

Output power 
per channel at 4 ohms

600W

Output power 
per channel at 8 ohms

390W

Output power in bridge 
mode at 8 ohms

1200W

Frequency Response

15Hz-75kHz 
+0dB -3dB

Distortion

Better than 0.03%

Input Sensitivity

1Vrms

Voltage Gain

49.0

Slew Rate

>41V/us

Damping Factor

>450:1

Signal to Noise

Better than 97dB

Input Impedance

20kohm

Input clipping

+20dBV

Cooling

Front to Back

Amplifier Indicators

Power, Status(Signal/
Clip), Overload,
Thermal, Fault

Amplifier Controls 

Volume, Ground Lift,
Bridge Switch, Limiter

Amplifier Protection 

Current Limiting, DC
Protection, mains fuse,
DC rail fuses, Slow
Start, Thermal Cutout

Dimensions

87x482x450

Net weight

15kg

Shipping weight

17kg

Shipping dimensions

210x540x520

SY1600

Output power 
per channel at 4 ohms

800W

Output power 
per channel at 8 ohms

490W

Output power in bridge 
mode at 8 ohms

1600W

Frequency Response

15Hz-62kHz 
+0dB -3dB

Distortion

Better than 0.03%

Input Sensitivity

1Vrms

Voltage Gain

56.5

Slew Rate

>41V/us

Damping Factor

>430:1

Signal to Noise

Better than 97dB

Input Impedance

20kohm

Input clipping

+20dBV

Cooling

Front to Back

Amplifier Indicators

Power, Status(Signal/
Clip), Overload,
Thermal, Fault

Amplifier Controls 

Volume, Ground Lift,
Bridge Switch, Limiter

Amplifier Protection 

Current Limiting, DC
Protection, mains fuse,
DC rail fuses, Slow
Start, Thermal Cutout

Dimensions

87x482x450

Net weight

18kg

Shipping weight

20kg

Shipping dimensions

210x540x520

Engineered and Distributed by

Audio Telex
Communications Pty Ltd

ABN 78 001 345 482

149 Beaconsfield Street, 
Silverwater, Sydney NSW 2128,
Australia

NSW Tel

(02) 9647 1411

Fax

(02) 9648 3698

VIC  Tel

(03) 9890 7477

Fax

(03) 9890 7977

QLD Tel

(07) 3852 1312

Fax

(07) 3252 1237

SA

Tel

(08) 8352 4444

Fax

(08) 8352 4488

WA

Tel

(08) 9228 4222

Fax

(08) 9228 4233

NZ

Tel

(09) 415 9426

Fax 

(09) 415 9864

International Enquiries

[email protected]

Website

www.australianmonitor.com.au

UNLIKE MOST AMPLIFIERS IN
THIS PRICE BRACKET, 
THE SYNERGY SERIES DOES
SOUND EXCEPTIONALLY GOOD 
- PLEASE COMPARE!
•  It is very reliable 
•  It is very well constructed 
•  It features in-built clip limiting 
•  Ground Lift Facility 
•  Twin fans for efficient cooling 
•  It is genuinely suitable for

installations and hire
applications 

•  Industry standard XLR inputs

and speakon/binding post
outputs

FIVE SOLID LEVELS OF
PROTECTION:
• Overload 
•  Output Short Circuit 
• Thermal 
•  Output DC Protection 
•  Slow Start Facility

FIVE STAGE INDICATION:
• Power 
• Status/Clip 

(L/R) 

• Overload 
• Thermal 
•  Fault

Reviews: