AMP 1
AMP 5
AMP 2
AMP 6
AMP 3
AMP 7
AMP 4
AMP 8
INPUT FROM 100V LINE AMP.
+
+
+
+
+
+
+
+
ZONE 1
ZONE 5
ZONE 2
ZONE 6
ZONE 3
ZONE 7
ZONE 4
ZONE 8
OUTPUT TO 100V SPEAKERS
+
+
+
+
+
+
+
+
24 VDC IN
12-24V AC/DC
TIP +VE
+
ENGINEERED BY AUDIO TELEX COMMUNICATIONS PTY LTD SYDNEY AUSTRALIA
1
2
3
4
²
Labels:
This area is available to custom label the zones each amplifier is driving.
³
Power On LED:
This indicates there is power to the unit.
´
Power Switch:
This switch switches power from the AC/DC plug pack input.
NOTE:
When using 24VDC IN terminals the unit is on regardless of switch position.
NOTE:
When using 24VDC IN terminals the power LED will always be on.
NOTE:
The terminal lug accepts wire gauges from AWG22 (0.75mm) up to
AWG16 (1.5mm). Each terminal is rated at 15A/300VAC.
12-24V AC/DC
TIP +VE
3. BACK PANEL
¬
Power Socket:
This 2.1mm socket accepts AC or DC voltage between 12V and 24V.
For DC, tip is positive.
24VDC In Binding Posts:
These binding posts provide connection for 24V emergency systems
and is not switched by the front panel power switch. The 24VDC IN
does not provide trickle charge facility.
®
Input Terminal Strip:
Paired connection from each amplifier in the system. The label AMP
‘X’ corresponds with AMPLIFIER ‘X’ on the selector switches.
¯
Output Terminal Strip:
Paired connection to each zone speaker distribution, wired in
parallel with input terminal strip.
INSTALLATION SERIES
Australian Monitor
INSTALLATION SERIES
Australian Monitor
6
7
NOTE:
The MP8 will accept input from both constant voltage systems and low