CONTROLS, CONNECTORS & INDICATORS

REAR PANEL

8

  Mains Input Connector

The AMH2400 is fitted with a standard 3 pin IEC 60320-C14 socket.  
The AMH3600 is fitted with a high current 3 pin IEC 60320-C20 socket.  
Use the mains cable supplied with the unit to power up the unit. 

 

NOTE:

 Your unit must always be earthed!

 

IMPORTANT:

 The AMH3600 is a high current 16A mains inlet and 

does NOT accept standard IEC60320-C13 power cords.

9

  Mains Circuit Breaker

The amplifier is fitted with a resettable circuit breaker. If the circuit breaker 
trips, allow 3 minutes for the contacts to reset thermally before pushing the 
reset button to reset it mechanically.

10  

  Binding Post Outputs

Touch proof binding posts (banana jacks) are provided for speaker output 
termination with banana plugs or bare wire. The red post is used as positive 
and the black post is used as negative. For bridge connection, use only the  
red posts.

11    

  Speaker Output Connector

A 4 pole Neutrik speakON connector is provided as an additional speaker 
output. This standard of loudspeaker-amplifier connection allows access to  
both channels of the amplifier via the one connector for biamp applications. 
Channel 1 is considered the dominant channel and has both channels wired  
to the speaker connector. See the installation section of this manual for  
detailed information on speaker connector wiring.

12    

  Balanced Input

A female 3-pin XLR type connector is provided on each input:

Pin 1 = Signal Ground;

Pin 2 = Hot (non-inverting or in phase);

Pin 3 = Cold (inverting or reverse phase).

13    

  Signal Strapping

A male 3-pin XLR type connector is provided and wired in parallel with the 
female input XLR for strapping / looping signal between amplifiers.

14    

  Bridge / Stereo / Mono (parallel)

Keeping this switch in middle position engages the BRIDGED/ MONO mode of 
operation. In this mode your amplifier will only accept signal applied to channel 
1’s input XLRs and the level of both channels will be controlled by the channel 
1 attenuator. The output from channel 2 will automatically be of the opposite 
polarity (reversed phase) and speaker termination should be sourced from the 
red binding-post outputs.

Alternatively, the speaker could be connected to poles 1+ & 2+ of the 4 pole 
speaker connector (See Installation Output Wiring on Page 7). Keeping this 
switch in bottom position will run the amplifier in stereo mode. Keeping this 
switch in top most position will run the amplifier in mono (parallel) mode. In  
this case also CH 1 level control will control both the channels.

15    

  Limiter Switch

Adjust the switch to the ON position to engage the clip limiter circuitry. The 
threshold level is referenced to the supply rail and the output voltage is 
sampled allowing true clip detection and limiting.

16    

  Signal Ground Lift Switch

Adjust the switch to the ON position to disconnect signal ground from the input 
connectors on both channels. It is intended to be used when “hum” is caused by 
earth loops (due to different ground potentials between source equipment and 
the amplifier) or stray magnetic field pick up on the input ground/shield wiring. 
(It does not interrupt signal ground continuity on the strapping connector). The 
amplifier should be turned off before engaging this switch!

17    

  Filter Switch

Individual channel selectable low pass filter (LPF) or high pass filter (HPF).  
The filter is a Linkwitz-Riley operating at 120Hz with a 12dB/octave attenuation.

8

14 16

13

12

9

10

11

15

17

Rear panel for AMH3600 shown. Rear panel controls, connectors & indicators are the same for AMH2400.

Summary of Contents for AMH2400

Page 1: ...INSTALLATION AND OPERATION MANUAL AMH SERIES PROFESSIONAL AUDIO POWER AMPLIFIERS AMH3600 AMH2400 ...

Page 2: ...peaker wiring during normal operation 1 LISEZ ces instructions 2 Tenez ces instructions 3 Notez tous les avertissements 4 Suivez toutes les avertissements 5 N utilisez pas ce produit près de l eau la piscine la plage le lac etc 6 Nettoyez seulement avec une étoffe sèche 7 Ne bloquez aucuns troux de ventilation Installez en accord avec les instructions du manufacturier 8 N installez près aucunes so...

Page 3: ... TO PREVENT BLADE EXPOSURE TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE TO PREVENT ELECTRICAL SHOCK MATCH WIDE BLADE PLUG TO WIDE SLOT FULLY INSERT CAUTION THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED SERVICE PERSONNEL ONLY TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE OPERATING INSTRUCTI...

Page 4: ...o bridged Mono parallel operation selectable Binding post and 4 pole speaker output connection Output clip indication per channel Multi role output fault indication High quality close tolerance components throughout Individual 7 step Signal LED Bar Graph for status indication per channel Filter selectable switch LPF HPF per channel Protection Features Suppression of inrush current at mains turn on...

Page 5: ...en the amplifier will remain muted 4 Attenuator Level control for your amplifier is provided by a potentiometer on the front panel and indicates gain There are 2 controls on the new AMH Series amplifiers Each control is labelled for the channel that it operates 5 Signal Bar Graph Indicator There is a 7 step LED Bar graph given on the front panel for each channel They indicate 0dB 3dB 6dB 9dB 12dB ...

Page 6: ...with the female input XLR for strapping looping signal between amplifiers 14 Bridge Stereo Mono parallel Keeping this switch in middle position engages the BRIDGED MONO mode of operation In this mode your amplifier will only accept signal applied to channel 1 s input XLRs and the level of both channels will be controlled by the channel 1 attenuator The output from channel 2 will automatically be o...

Page 7: ...ipment s output wiring When wiring for an unbalanced source Pin 1 GROUND SHIELD Pin 2 HOT in phase with the amplifier s output Pin 3 GROUND SHIELD joins to pin 1 NOTE In line XLR connectors often have a termination lug that connects directly to the chassis of the connector IMPORTANT Do not link this lug to pin 1 at the amplifier s input as it will defeat the amplifier s input grounding scheme Outp...

Page 8: ...source equipment earth appears to the amplifier s input as a signal and is amplified as hum There are three things you can do to avoid earth loop problems Ensure the mains power for the audio system is quiet i e without equipment on it such as airconditioning refrigeration or lighting that may generate noise in the earth circuit Ensure all equipment within the system shares a common ground safety ...

Page 9: ... initialising period before it will accept signal The Inrush Current Suppression ICS circuit is in operation for the first 0 5 seconds This limits the mains current to prevent nuisance tripping of circuit breakers During this period you will hear a couple of relays click indicating mains is now directly applied to the amplifier and the signal path is connected While the ICS circuit operates there ...

Page 10: ...g edge of the fan blades and reduce their cooling efficiency The time taken for this to happen will depend on the environment and the amount of use The fan blades are accessible once the lids are removed and can be easily cleaned You need only hold the fan rotor still and wipe the dust off the blades Many users stall the fan and use compressed air to blow the dust off the fan blades It is importan...

Page 11: ...Channel Separation crosstalk 65dB 65dB 20Hz 20kHz Max output Adjacent Channels Damping Factor 400 400 20Hz 1kHz 8Ω Input Connectors 2 Female XLR 2 Male XLR 2 Female XLR 2 Male XLR Input Impedance 22kΩ 22kΩ Balanced line to line Output Impedance 20mΩ 20mΩ Input Sensitivity 1 23Vrms 4 0dBu 1 23Vrms 4 0dBu 0 2V Level control at maximum Input CMRR 55dB 55dB 20Hz 20kHz Output Connectors 2 Binding Posts...

Page 12: ...r 4200W 5700W 230Vac 50Hz Bridged 4Ω Efficiency Pink noise IEC 60268 1 Pink noise IEC 60268 1 1 8th Power 28 33 230Vac 50Hz Bridged 4Ω 1 3 Power 46 52 230Vac 50Hz Bridged 4Ω Full Power 57 63 230Vac 50Hz Bridged 4Ω Thermal Dissipation Pink noise IEC 60268 1 Pink noise IEC 60268 1 Idle 177 205 Excludes Load Power 1W 3 412BTU Hr 1 8th Power 2661 3166 Excludes Load Power 1W 3 412BTU Hr 1 3 Power 3190 ...