REAR PANEL

1

2

3

4

6

1

 CH 1–4

Each channel input section has two inputs: XLR input – This 
is a balanced microphone input. It has an input sensitivity of 
1mV. RCA input – This is an unbalanced line level input. It 
has an input sensitivity of 500mV. The two RCA sockets are 
summed to mono internally.

2

 REC Output

The REC output is on unbalanced RCA connectors. The output 
level is 150mV into 10kohm at rated output. The output is 
dual mono. 
The REC output is not affected by the MASTER volume control 
or the BASS and TREBLE controls. 
The REC output does not receive the tone signal if the optional 
tone generator module is installed.

3  

 Line Output

The LINE output is on a balanced XLR connector. The output 
level is 0.775V into 1k at rated output.

Note:

 When wiring the LINE output as unbalanced, Pin2 

should be wired as hot and Pin1 should be wired as ground/
shield. Do not wire Pin3.

 

4    

 Direct Out

The speaker connections are on the 12 pole terminal strip. 
There is a low impedance output (OHM) and a distributed line 
voltage output (LINE). 70V out is available on 115V models. 
100V out is available on 230V/240V models.

Note:

 Only connect one output – either Distributed Line or Low Impedance per channel. 

Do not connect LowZ and 70/100V at the same time.

The output strip comes fi tted with a touch-proof cover held in place by two M3 machine screws 
with fl at and spring washers.

5    

  IEC Mains Input Socket

This is a standard IEC 3 pin socket. It accepts a standard IEC mains cable, provided. The fuse 
draw at 5 contains the mains fuse and a spare. The mains fuse is a time lag (slow blow) 
HRC 20mm x 5mm ceramic type fuse.

 Always replace the fuse with one of the same value and type.

 Note:

 Always disconnect power to the amplifi er before replacing fuses.

6    

 (Optional) Tone Module

These terminals are for use with an optional tone module (not supplied). Use Australian Monitor 
ATC5488 module.

7    

  Phantom Power

12V phantom power is available for condenser or electret microphones on the XLR input when 
this switch is pushed in.

Minimum Impedance 

AMC

+

30  

AMC

+

60  

AMC

+

120 AMC

+

250

Distributed Line Output

 

70V (115V version)  

166ohm  

83ohm  

41ohm 

20ohm

 

100V (230/240V version)  

333ohm  

166ohm  

83ohm 

40ohm

Low Impedance Output

 

(both versions) 

 4ohm  

4ohm  

4ohm 

4ohm

The ratings are:

 

AMC

+

30  

AMC

+

60  

AMC

+

120 AMC

+

250

230V/240V model 

0.5A  

1.6A  

2A 

2.15A

115V model  

1A  

3.15A  

4A 

6.3A

5

7

Summary of Contents for AMC+ SERIES

Page 1: ...AMC SERIES 30W 60W 120W 250W MIXER AMPLIFIERS INSTALLATION AND OPERATION MANUAL ...

Page 2: ...fan intake or exhaust ports Do not operate equipment on a surface or in an environment which may impede the normal flow of air around the unit such as a bed rug weathersheet carpet or completely enclosed rack If the unit is used in an extremely dusty or smoky environment the unit should be periodically blown free of foreign matter 14 Do not remove the cover Removing the cover will expose you to po...

Page 3: ...Rev B 6th Jun 2006 Rev C 26th May 2008 This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the products enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons This symbol is intended to alert the user to the presence of important operational and maintenance servicing instructions in the literature accompanying t...

Page 4: ...each channel input 2 Bass There is 12dB of cut and boost at 100Hz 3 Treble There is 9dB of cut and boost at 10kHz 4 Master This controls the overall mixed output level 5 On This LED indicates the unit is powered on 6 Power This switch switches power on or off the mains The up position is on 5 6 2 3 4 1 ...

Page 5: ... available on 115V models 100V out is available on 230V 240V models Note Only connect one output either Distributed Line or Low Impedance per channel Do not connect LowZ and 70 100V at the same time The output strip comes fitted with a touch proof cover held in place by two M3 machine screws with flat and spring washers 5 IEC Mains Input Socket This is a standard IEC 3 pin socket It accepts a stan...

Page 6: ... 0 75mm2 AWG16 1 5mm2 AWG13 2 5mm2 70V Up to 50m AWG26 0 12mm2 AWG24 0 2mm2 AWG22 0 35mm2 AWG18 0 75mm2 50m 200m AWG20 0 5mm2 AWG18 0 75mm2 AWG16 1 5mm2 AWG13 2 5mm2 Over 200m AWG18 0 75mm2 AWG16 1 5mm2 AWG13 2 5mm2 AWG10 6 0mm2 4 ohm Up to 10m AWG18 0 75mm2 AWG18 0 75mm2 AWG18 0 75mm2 AWG18 0 75mm2 10m 30m AWG13 2 5mm2 AWG13 2 5mm2 AWG13 2 5mm2 AWG13 0 35mm2 Over 30m Not Recommended Not Recommend...

Page 7: ... at source Reduce volume levels on front panel Reduce Bass control level No sound but amp is on Volume controls down Amplifier has overheated AMC 60 AMC 120 AMC 250 only DC fuse s blown Check volume controls Check for obstructions above and below Make sure the amplifier is well ventilated Refer product to local Australian Monitor dealer No sound from channels 2 and 3 Priority function is being use...

Page 8: ...NTS PRIORITY Channel 1 will mute channels 2 3 and 4 This will only occur when signal appears on channel 1 irrespective of the channel volume control Priority can be disabled See below The release time is approx 3 secs and is NOT adjustable The mute depth is approx 40dB and is not adjustable ...

Page 9: ...PAGE 9 AMC SERIES INSTALLATION AND OPERATION MANUAL DIMENSIONS ...

Page 10: ...16 5lb 23 1lb 27 6lb 30 8lb SHIPPING DIMENSIONS WXHXD 510 x 145 x 297mm 525 x 175 x 385mm 525 x 175 x 385mm 525 x 185 x 470mm 20 1 x 5 7 x 11 7 20 7 x 6 9 x 15 2 20 7 x 6 9 x 15 2 20 7 x 7 3 x 18 5 MAINS CURRENT DRAW 240V FULL POWER 0 35A 0 66A 1 20A 2 53A 1 3 POWER 0 23A 0 44A 0 80A 1 61A 1 8 POWER 0 17A 0 32A 0 55A 1 10 IDLE 0 08A 0 13A 0 15A 0 15A MAINS CURRENT DRAW 115V FULL POWER 0 73A 1 38A ...

Page 11: ...n 0 5 MIC INPUT SENSITIVITY 1mV 200ohm IMPEDANCE 1k3 ohm HEADROOM 77mV 37dB AUX INPUT SENSITIVITY 0 5V 100kohm IMPEDANCE 200kohm HEADROOM 15V 30dB TONE CONTROL BASS 100HZ 12 dB TREBLE 10KHZ 9 dB LINE OUT NOMINAL OUTPUT 0 775V 1kohm OUTPUT IMPEDANCE 100ohm REC OUT NOMINAL OUTPUT 250mV 10kohm OUTPUT IMPEDANCE 1kohm ...

Page 12: ... 31 Walsh Street Thebarton SA 5031 PO Box 157 Hindmarsh SA 5007 Phone 08 8352 4444 Fax 08 8352 4488 Email sa audiotelex com au PERTH WA SALES 3 11 Howe Street Osborne Park WA 6017 PO Box 1281 Osborne Park BC WA 6916 Phone 08 9204 0200 Fax 08 9244 3783 Email wa audiotelex com au AUCKLAND NZ SALES 9C Piermark Drive Albany 0752 New Zealand PO Box 300 512 Albany 0752 Phone 09 415 9426 Fax 09 415 9864 ...

Reviews: