Power Output

4 x 60 Watts RMS 

Maximum Load Per Amplifier

160 Ohms @ 100 Volts

Power Bandwidth

60Hz - 15kHz  < 0.5% THD

Frequency Response

60Hz - 15kHz (± 3dB)

Total Harmonic Distortion

0.5% @ 1kHz rated power

Signal To Noise Ratio

-74dB with all controls at their centre position

Tone Controls

Bass @ 100Hz: Boost +12dB Cut -12dB; Treble @ 10kHz: Boost +9dB Cut -9dB 

Inputs

Three mic/aux universal inputs  per mixer amplifier module. 

Mic/Line selection can be made via an internal dip switch

Input Sensitivity

Mics: 1mV @ 200 Ohms; Aux 75mV @ 47K Ohms

Outputs

Speaker: 100, 70 Volts, 8 Ohms

VCA Master Level Control

Via a 1K pot added to the rear barrier strip of each amplfier module

Phantom Power

Selectable per input of each amplifier module via an internal dip switch. 18 V

Controls

3 Input channel gain controls, 1 Bass control, 1 Treble control, 

1 Master VCA gain control per amplifier

Indicators

Power “on” LED

Power Source

AC 240V - 60Hz, 110V - 50Hz (special) 3 pin IEC connector

Power Consumption

400 Watts

Protection

Overload and overdrive protection, plus AC and DC fuses

Dimensions/Weight

88mm H x 480mm W x 350mm D (Chassis Dimensions only). 17kg

Rack Mounting

Standard

Tone Generators

Optional four tone generator module. Includes Bell, Pre-Announce, 

Alert and Evac Tones, plus a vox triggered relay output.

Muting

Built-in VOX muting. Channel 1 will mute channels 2 and 3  per amplifier

Engineered and Distributed By AUDIO TELEX COMMUNICATIONS PTY LTD (

ABN 78 001 345 482

), 149 Beaconsfield Street, Silverwater, Sydney, NSW, 2128 Australia

NSW Tel: (02) 9647 1411 Fax: (02) 9648 3698   VIC Tel: (03) 9890 7477 Fax: (03) 9890 7977   QLD Tel: (07) 3852 1312 Fax: (07) 3252 1237   WA Tel: (08) 9228 4222 Fax: (08) 9228 4233   

TAS Tel: (03) 6228 6373 Fax: (03) 6278 1063   SA Tel: (08) 8352 4444 Fax: (08) 8352 4488   Export Enquiries: [email protected]   

Website: www.australianmonitor.com.au

ARCHITECTURAL AND ENGINEERING SPECIFICATIONS

The four channel mixer amplifier shall have three universal input channels, accessible via a rear panel

barrier strip on each of the four amplifier modules. Each amplifier module shall allow remote VCA con-

trol of the master output. Phantom power selection on a per channel, per amplifier basis shall also be

included. A Vox triggered output shall also be available on an optional four tone generator card.

Each amplifier master section shall include one master VCA accessible gain control, two EQ controls,

one with 12dB of cut and boost at 100Hz and the other with 9dB of cut and boost at 10kHz. Speaker

outputs shall be transformer isolated at 100 volt, 70 volt  & 8 ohms. The amplifiers must be capable of

delivering 60 watts RMS into a 160 ohm inductive load, with less than 0.5% distortion measured at 

1 kHz and with system hum and noise of -74dB or better. 

The amplifier shall be an Australian Monitor Installation Series model ACM604.