Engineered and Distributed By AUDIO TELEX COMMUNICATIONS PTY LTD (
ABN 78 001 345 482
),
149 Beaconsfield Street, Silverwater, Sydney, NSW, 2128 Australia
NSW Tel: (02) 9647 1411 Fax: (02) 9648 3698 VIC Tel: (03) 9890 7477 Fax: (03) 9890 7977 QLD Tel: (07) 3852 1312 Fax: (07) 3252 1237
WA Tel: (08) 9228 4222 Fax: (08) 9228 4233 TAS Tel: (03) 6228 6373 Fax: (03) 6278 1063 SA Tel: (08) 8352 4444 Fax: (08) 8352 4488
Export Enquiries: [email protected]
Website: www.australianmonitor.com.au
Power Output
120 Watts RMS
Maximum Load
80 Ohms @ 100 Volts
Power Bandwidth
60Hz - 15kHz < 0.5% THD
Frequency Response
60Hz - 15kHz (± 3dB)
Total Harmonic Distortion
0.5% @ 1kHz rated power
Signal To Noise Ratio
-80dB
Input Sensitivity
700mV
Outputs
100V, 70V, 4 Ohm, 8 Ohm
Controls
One gain control on rear of the unit via flathead screwdriver control
Indicators
Power “on” LED
Power Source
AC 240V - 60Hz, 110V - 50Hz (special) 3 pin IEC connector
Power Consumption
300 Watts
Protection
Current Limiter protection, plus AC and DC fuses
Dimensions/Weight
88mm H x 480mm W x 280mm D (Chassis Dimensions only). 12kg
Rack Mounting
Standard
ARCHITECTURAL AND ENGINEERING SPECIFICATIONS
The 120 watt power amplifier shall be designed to run 100 and 70 volt line audio systems. The unit shall
also feature a 4 and 8 ohm output. The amplifier may be desk or rack mounted.
The amplifier must be capable of delivering 120 watts into an 80 ohm inductive load with less than 0.5%
distortion measured at 1kHz and with system hum and noise of -80dB or better. Internal current limit-
ing shall protect the amplifier from both overload and overdrive conditions.
The amplifier shall be an Australian Monitor Installation Series model ACM120P.