Austin Springs AS-RO-75 Owner'S Manual Download Page 7

11

10

RO SYSTEM MAINTENANCE

This RO system is designed with ease of use and low maintenance in mind  If you change the filter 
cartridges as suggested below, and check TDS level periodically, the system will work properly for 
many years  For filter replacements, visit AustinSprings com

Stages 1, 2 & 3: 

Replace every 6 months, or sooner if water flow gets slow.

The actual performance of the filters depends on your water   We recommend changing every six 
months  Sooner if you are on well water or you notice heavy sediments and particles in through the 
clear housing 

(stage 1)

 

How to replace stage 1, 2 & 3 filter cartridges

1  Turn off water supply and tank valves  Open RO faucet to depressurize   Place a towel or bucket 

under the unit to catch any spills 

2  Remove system from under sink location  If the system is attached to the wall, it may be 

feasible to remove the filter housing in place   If not, pull the system out and gently place it on 
a towel   Use caution to keep the tubing connections in place 

3  Twist filter housing counter-clockwise to unscrew it   Use the large housing wrench if 

necessary 

4  Refer to Installation Step 4 

(p7)

 to install replacement filter and reattach as instructed 

5  Flush the system   

Stage 4: 

Replace every 2 – 3 years or sooner if TDS level starts increasing.

Check the TDS level at least once a month to monitor the system performance  The rejection rate 
should be above 90% 

(NSF/ANSI STANDARD 58 for RO water filter)

  Reverse osmosis membrane usually 

last 2 – 3 years, depending on the source water quality and the replacement schedule of the three 
pre-filters  To ensure system performance and water purity, filter cartridges must be replaced on 
schedule 

How to replace the reverse osmosis membrane

1  Turn off water supply and tank valves  then open RO faucet to depressurize   Place a towel or 

bucket under the unit to catch any spills 

2  Remove the tubing from the inlet fitting on the membrane housing cap  Unscrew the housing 

cap 

(counter-clockwise looking from inlet)

  Use a housing wrench if needed  

3  Pull out the old membrane  Use screwdriver or pliers to apply leverage if necessary 

4  Clean the housing using hot water and scent-free dish soap  Rinse thoroughly  Cut open the 

small end of the sealed bag of a new RO membrane  Hold the membrane with the bag to avoid 
contamination and insert it into the housing  

(Step 6, p8.)

5  Check the O-ring on the open end of the membrane housing  It is recommended to replace it 

every 3 years to prevent leaks 

6  Twist the membrane housing cap back on by hand  Use a wrench for a final 

¼

 turn if necessary  

DO NOT overtighten 

7   Flush the system 

Stage 5: 

Replace every 12 months

This entire cartridge is replaced by removing the elbow fittings on both ends and using them for 
the new cartridge 

How to replace the stage 5 inline cartridge

1  Disconnect the tubing from the Quick-Connect fitting on both ends  Unscrew each fitting  

Unwrap a new cartridge, replace the Teflon tape on the fitting threads if necessary, follow the 
arrow sign on the label to screw the correct fitting on each end, and reconnect the tubing 

O-rings: 

Replace every 3 years or sooner if leak happens at O-ring.

The package comes with 3 spare O-rings for the pre-filter housing, and 1 spare O-ring for the 
membrane housing  Please save them with this manual 

Stage 1

Stage 2

Stage 3

Stage 4

Stage 5

Summary of Contents for AS-RO-75

Page 1: ...Reverse Osmosis Water Filter System Model AS RO 75 Owner s Manual Installation and Maintenance ...

Page 2: ...stin Springs Reverse Osmosis filter you have delicious filtered water right from your tap Once installed keep this owner s manual for reference as it has both installation and maintenance information Enjoy Before Installation Inspect the package Open the box and confirm the included parts If by chance any parts are missing or you have any questions contact AustinSprings Customer Support at 866 238...

Page 3: ...4 Remove the blue Lock Clip and insert the tubing into the Lock Sleeve until the mark nearly disappears Return the Lock Clip To Disconnect 1 Remove the blue Lock Clip 2 Gently push the Lock Sleeve down with two fingers to where the blue Lock Clip was removed 3 Pull to remove 1 4 Tank Valve Parts Included RO Manifold System Cover CTO Carbon Filter Storage Tank Tank Stand Faucet Install Kit Housing ...

Page 4: ...be performed by a qualified and certified installer TIP 4 Converting the Water Feed Adapter to a different size The included Water Feed Adapter can be converted on either side of the valve to make a 3 8 x 3 8 COMP or 1 2 x 1 2 NPT Installation Diagram This overview provides a visual for how the system 4 colored tubes are connected between water source and the RO system A Water Feed Adapter B Water...

Page 5: ...3 Place each filter cartridge into its housing Make sure the center hole of each filter is aligned onto the raised ring at the bottom of each housing 4 Screw each filter housing with loaded cartridges into the RO manifold Ensure each cartridge is aligned to each of the center posts of the RO manifold Twist clockwise by hand Use housing wrench to tighten about 1 4 turn Overtightening may cause dama...

Page 6: ... NOT use first tank of water Water will surge from faucet When it slows to a trickle the tank is empty and can be refilled for use 8 For the first two weeks following installation check for leaks daily Optional Place a bucket under system or use the included Water Detector Alarm in case of leaks 9 Test RO water periodically to verify effective reduction of total dissolved solids TDS If the TDS of ...

Page 7: ...e three pre filters To ensure system performance and water purity filter cartridges must be replaced on schedule How to replace the reverse osmosis membrane 1 Turn off water supply and tank valves then open RO faucet to depressurize Place a towel or bucket under the unit to catch any spills 2 Remove the tubing from the inlet fitting on the membrane housing cap Unscrew the housing cap counter clock...

Page 8: ...ow 300 and connects to the drain line Low tank pressure Cloudy water With a new system air bubbles in water or ice may occur and normally clears up in two weeks If cloudyness persist check the membrane with a TDS meter If the meter reads below 75 rejection the membrane needs to be replaced High TDS level in RO water The RO system should produce a TDS rejection rate of about 85 95 Check the followi...

Page 9: ...tin Texas 78701 866 238 5855 www AustinSprings com Manufactured in Facility 2 How to reach us Phone 866 238 5855 Office Hours Monday Friday 9 00 a m 5 p m CST Technical Support Hours Monday Friday 9 00 a m 5 00 p m CST AS RO 75 OM 20170901 ...

Reviews: