Aurora THE ELEMENTAL SUSPENDED FIRE Installation And User Manual Download Page 11

AURORA SUSPENDED FIRES

11

CEILING BRACKET

FLUE

FIREBOX

Summary of Contents for THE ELEMENTAL SUSPENDED FIRE

Page 1: ...www aurorasuspendedfires com 61 0 2 6686 8408 4 1 Simmons Street Ballina NSW 2478 Australia INSTALLATION AND USER MANUAL THE ELEMENTAL SUSPENDED FIRE Bioethanol...

Page 2: ...2...

Page 3: ...IONS 10 3 INSTALLATION SUSPENSION BRACKET 14 LOWER FLUE 16 FIREBOX 18 BIOETHANOL FIREPLACE 19 FOR INSTALLERS 20 INSTALLATION CHECKLIST 21 We would like to thank you for your purchase of an Aurora Susp...

Page 4: ...4...

Page 5: ...1 PLANNING...

Page 6: ...on of firebox and flue ensuring that you follow the clearances described within this section 2 Install the suspension bracket 3 Install the lower flue 4 Engage the firebox 5 Fit the blanking plate to...

Page 7: ...on combustible material Timber frames behind gyprock are considered combustible IMPORTANT Window frames must also be considered Timber window frames must be treated as combustible surfaces Aluminium f...

Page 8: ......

Page 9: ...2 DIMENSIONS SPECIFICATIONS...

Page 10: ...Colour matte black A range of other colours are available on request For more information visit our website THE ELEMENTAL 2 DIMENSIONS SPECIFICATIONS Firebox length 950mm Firebox width 360mm Firebox h...

Page 11: ...AURORA SUSPENDED FIRES 11 CEILING BRACKET FLUE FIREBOX...

Page 12: ......

Page 13: ...3 INSTALLATION...

Page 14: ...G IS MADE FROM A NON COMBUSTIBLE MATERIAL SUCH AS CONCRETE CEILING FLAT CEILING INSTALLATION The bracket must be structurally secured within the roof as shown on the diagram The large square body of t...

Page 15: ...h 10 degree bracket 15 to 25 degree pitch 20 degree bracket 25 to 35 degree pitch 30 degree bracket 35 to 45 degree pitch 40 degree bracket A custom bracket is available for anything larger than a 45...

Page 16: ...TWO PIECE LOWER FLUE Lower flues over 3 metres are supplied in two parts and are joined internally with a flue connector This assists installers in achieving a safe and successful installation Do not...

Page 17: ...ion the lower flue inside the suspension bracket 900mm from the floor 2 Once the 900mm height is achieved tighten the 8 grub screws Use a level to ensure that the flue is perfectly vertical GRUB SCREW...

Page 18: ...HE FIREBOX 1 Ensure the lower flue is the correct height from the floor 2 Use a jacking trolley to lift the firebox evenly onto the 4 fixing bolts 3 Fit the blanking plate to cover the opening in the...

Page 19: ...fireplace is fitted with an EcoSmart XL500 burner which uses bioethanol fuel As bioethanol gives off nothing but water vapour there is no need for an external flue The lower active flue will be blanke...

Page 20: ...of WINDEX if required DO NOT RUB THE PAINT A LIGHT PRESSURE IS ALL THAT IS NEEDED HANDING OVER CHECKLIST Read the Users instructions and instruct the user on the operation of the fireplace and cleanin...

Page 21: ...nce gap between the bracket and the ceiling This gap will be covered by the ceiling cover plate Lower flue installed 900mm from the floor Grub screws tightened Firebox lifted into position evenly to p...

Page 22: ...61 0 2 6686 8408 4 1 Simmons Street Ballina NSW 2478 Australia www aurorasuspended res com Aurora...