background image

 

15

 ~ 

 

 
 

RS-232 Communication settings & protocol: 

Baud rate: 9600         Data bit: 8         Stop bit: 1         Parity: none 

Command 

Types 

Command 

Codes 

Functions 

 

System

 Command 

/*Type; 

Request model’s information 

/%Lock; 

Lock the keyboard of control panel on the Matrix. 

/%Unlock; 

Unlock the keyboard of control panel on the Matrix 

/^Version; 

Request firmware version  

/:MessageOff;  Turn off feedback. It will only show “Switcher OK” 
/:MessageOn; Turn 

on 

feedback 

EDIDMOn. 

Manually adjust the EDID with the most priority output 
port. 

EDIDMInit. 

Recover the factory default EDID data 

Undo. Cancel 

previous 

operation 

Demo. 

Switch to “demo” mode, 1->1, 2->2, 3->3 … 

[x1]All. 

Transfers all signals from input channel [x1] to all output 
channels  

All#. 

Transfers all input signals to the corresponding output 
channels respectively.  

All$. 

Switches off all output channels. 

[x1]#. 

Transfers signals from input channel [x1] to output 
channel [x1]. 

[x1]$. 

Switches off output channel [x1]. 

Operati

on Co

mm
an

[x1] V[x2].  

Transfers video signals from input channel [x1] to output 
channel [x2]. 

[x1] 
V[x2],[x3],[x4]. 

Transfers video signals from input channel [x1] to output 
channels [x2], [x3] and [x4].  

[x1] A[x2]. 

Transfers audio signals from the input channel [x1] to the 
output channel [x2].  

[x1] 
A[x2],[x3],[x4]. 

Transfer the audio signals from the input channel [x1] to 
the output channels [x2], [x3] and [x4]. 

[x1] B[x2]. 

Transfers both video and audio signals from input 
channel [x1] to output channel [x2]. 

[x1] 
B[x2],[x3],[x4]. 

Transfer both video and audio signals from input channel 
[x1] to output channels [x2], [x3] and [x4]. 

Status[x1]. 

Request input channel for output channel [x1].  

Status. 

Request input channel for output channels one by one. 

Communication Protocol

Summary of Contents for ASP-1616H

Page 1: ...ASP 816H ASP 168H ASP 1616H 8x16 16x8 16x16HDMIMatrix User Manual Manual Number 101001...

Page 2: ...mize the risk of damage to the unit z Follow all instructions and warnings marked on this unit z Do not attempt to service this unit yourself except where explained in this manual z Provide proper ven...

Page 3: ...urces to multiple destinations They can be used in broadcasting multimedia meeting rooms digital signage education residential and command control centers It also has an adaptable compensation to exte...

Page 4: ...ew any HDMI source at any time z Supports 7 1 channel digital audio z Supports default HDMI EDID and learns the EDID of displays if necessary z The matrix master can switch every output channels to an...

Page 5: ...annel DDC data using DVI and HDMI standards EDID and DDC signals are actively buffered The built in EDID DDC database can analyze these two signals mix them and realize the handshake of them internall...

Page 6: ...6 Packaging ASP 816H or ASP 168H or ASP 1616H Matrix Switcher depending on model ordered IR remote RS 232 Communication Cable Power Supply Cable CD User Manual and Warranty...

Page 7: ...channel No 2 to output channel No 3 Operation Press buttons in this order AUDIO 2 3 1 2 3 16 I O Keypads Number keys for I O channels Example To transfer input channel No 3 to output channel No 1 Ope...

Page 8: ...Output Channel Select the number of output channels to be controlled Examples of Operation Example 1 To transfer video and audio signals from input channel No 1 to output channel No 3 4 1 Press the bu...

Page 9: ...all the way to output 8 which has the least priority When the user carries out the EDID erase refresh function the ASP will detect the output priority and exchange the EDID data with the available mo...

Page 10: ...essing the arrow button for 30 seconds all the LED of will be on for 10 seconds It then enters the EDID setting status Pressing Input 2 button and Undo button all the outputs will be blank for 3 secon...

Page 11: ...d remote control The function buttons on the remote control are the same as the ones on the front panel The remote control shares the same control operation and command format as the front panel Input...

Page 12: ...onnectors The ASP 1616H has 16 input and output female HDMI ports while the ASP 816H has 8 inputs and 16 Outputs The ASP 168H has 16 inputs and 8 outputs Port numbers and other labeling can be found o...

Page 13: ...TMDS Data 2 20 SHELL 2 TMDS Data 2 Shield 19 Hot Plug Detect 3 TMDS Data 2 18 5V Power 4 TMDS Data 1 17 Ground 5 TMDS Data 1 Shield 16 DDC Data 6 TMDS Data 1 15 DDC Clock 7 TMDS Data 0 14 No Connect 8...

Page 14: ...ransmit 3 Rx Receive 4 N A Unused 5 Gnd Ground 6 N A Unused 7 N A Unused 8 N A Unused 9 N A Unused Connecting to a Computer Users can control the switcher by connecting it to the computer and by using...

Page 15: ...nals to the corresponding output channels respectively All Switches off all output channels x1 Transfers signals from input channel x1 to output channel x1 x1 Switches off output channel x1 Operation...

Page 16: ...4 16 16 3 Switch off all output channels All Example After running this command there will be no signals on all the output channels 4 Check firmware version Version Unit will reply back with the curr...

Page 17: ...put channel x Status x Example To inquire the input channel for output channel No 3 Run Command Status3 13 Request input channel for the output channels one by one Status Example To inquire the input...

Page 18: ...fected the performance safety or reliability of the product F Part s are no longer available for product In the event that the product needs repair or replacement during the specified warranty period...