XTR-8LR-REP
User manual
-------------------------------------------------------------------------------------------------------------------------------------------------------------------
The technical features can change without forecasting. AUR°EL S.p.A doesn’t assume any responsibility of damage due to the improper use of the device.
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Aurel S.p.A via Foro dei Tigli 4, 47015 Modigliana (FC) ITALY
06/06/2019 - Rev. 2.0
Tel:(+39)0546941124
, Fax:(+39)0546941660, http: www.aurelwireless.com
4.
Test the link between the XTR-8LR-REP #1 and the keyfob pressing the button on
the keyfob and verifying the reception of the ACK packet (green led ON for 600
msec).
TURN OFF THE XTR-8LR-REP
If it is necessary to turn off the device (e.g. for maintenance purposes) proceed as
follow:
1.
Shut off the main circuit breaker of the building.
2.
Turn the screws on the housing into position 0 (see Figure 2.1) and remove the
cover.
3.
If the BATTERY ENABLE JUMPER is closed, move the ON/OFF DIP SWITCH to the
OFF position.
Technical characteristic
Characteristics
Min.
Typ.
Max.
Unit
Power supply
85
264
VAC
Average power consumption
< 1
W
RF carrier frequency
868.3
MHz
European ISM Band
868 - 868.6
MHz
Modulation
LoRa™
ERP RF Power
13
dBm
Sensitivity
-126
dBm
Operating time without power supply
24
h
Box IP rating
IP 55
Manufacturer's Declaration of Conformity EU
Hereby, Aurel S.p.A. declares that the radio equipment type XTR-8LR-REP is in
compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity
is available at the following internet address:
http://www.aurelwireless.com/declaration-of-conformity/
The device operates at 868.3MHz (ISM frequency band 868.00 - 868.60 MHz) with
maximum radiated power of 13dBm.
The device is a “Class 1” radio equipment as defined in article 1(1) of European
Commission Decision No. 2000/299/EC of 06/04/2000. Class 1 radio equipments can be
placed on the market and be put into service without restrictions on all EU member
states.
Recommendation CEPT 70-03
The device operates in a harmonized frequency band and therefore, in order to comply
with current regulations, the device must be used on the time scale with a maximum
duty-cycle time of 1% (equivalent to 36 seconds usage on 60).
WEEE Marking
Once the product life-span has expired, the product must be
disposed of in a different way from other wastes. The user must to
put the equipment at the collection points for electronic and electrical
waste. Illegal disposing of this product, is punishable by law and will
be dealt with according to the laws of the individual member nation
of EU.
Figure 1
Figure 2
KEYFOB
XTR-8LR-REP
XTR-8LR-REP
XTR-8LR-DEC
Packet #1
Packet #2
Packet #2
Packet #3
Packet #3
Packet #4
1
2
3