4.

 

Test the link between the XTR-8LR-REP #1 and the keyfob pressing the button on 
the  keyfob  and  verifying  the  reception  of  the  ACK  packet  (green  led  ON  for  600 
msec).   

 
TURN OFF THE XTR-8LR-REP  

If  it  is  necessary  to  turn  off  the  device  (e.g.  for  maintenance  purposes)  proceed  as 
follow: 
1.

 

Shut off the main circuit breaker of the building. 

2.

 

Turn  the  screws  on  the  housing  into  position  0  (see  Figure  2.1)  and  remove  the 
cover. 

3.

 

If the BATTERY ENABLE JUMPER is closed, move the ON/OFF DIP SWITCH to the 
OFF position. 

 
Technical characteristic

 

 

Characteristics 

Min. 

Typ. 

Max. 

Unit 

Power supply 

85 

 

264 

VAC 

Average power consumption 

 

< 1 

 

RF carrier frequency 

 

868.3 

 

MHz 

European ISM Band 

 

868 - 868.6 

 

MHz 

Modulation 

 

LoRa™ 

 

 

ERP RF Power 

 

13 

 

dBm 

Sensitivity 

 

-126 

 

dBm 

Operating time without power supply 

24 

 

 

Box IP rating 

 

IP 55 

 

 

Manufacturer's Declaration of Conformity EU 

 
Hereby,  Aurel  S.p.A.  declares  that  the  radio  equipment  type  XTR-8LR-REP  is  in 
compliance with Directive 2014/53/EU. The full text of the EU declaration of  conformity 
is available at the following internet address: 
http://www.aurelwireless.com/declaration-of-conformity/ 
 
The  device  operates  at  868.3MHz  (ISM  frequency  band  868.00  -  868.60  MHz)  with 
maximum radiated power of 13dBm. 
The  device  is  a  “Class  1”  radio  equipment  as  defined  in  article  1(1)  of  European 
Commission Decision No. 2000/299/EC of 06/04/2000. Class 1 radio equipments can be 
placed  on  the  market  and  be  put  into  service  without  restrictions  on  all  EU  member 
states. 
 
 

Recommendation CEPT 70-03 

The device operates in  a harmonized frequency band  and  therefore, in order to comply 
with  current  regulations,  the  device  must  be  used  on  the  time  scale  with  a  maximum 
duty-cycle time of 1% (equivalent to 36 seconds usage on 60). 

 

 

WEEE Marking  

 

Once  the  product  life-span  has  expired,  the  product  must  be 
disposed  of  in  a  different  way  from  other  wastes.  The  user  must  to 
put the equipment at the collection points for electronic and electrical 
waste. Illegal disposing of this product, is punishable by law and will 
be  dealt  with  according  to  the  laws  of  the  individual  member  nation 
of EU.  

 

 
 

 
 
 
 
 
 
 
 
 

Figure 1 

 

   

 

 

 

 

 

Figure 2 

KEYFOB 

XTR-8LR-REP 

XTR-8LR-REP 

XTR-8LR-DEC 

Packet #1 

Packet #2 

Packet #2 

Packet #3 

Packet #3 

Packet #4 