![AUREL MAG 4M 5026 User Manual Download Page 3](http://html1.mh-extra.com/html/aurel/mag-4m-5026/mag-4m-5026_user-manual_3017641003.webp)
MAG 4M 5026
User Manual
Standard setting up
Installation:
1) Remove the front cover and the screw securing the card (see fig. 2).
2) Place the bottom of the sensor on the frame of the fixture, making sure to turn the magnetic sensor to
the moving part of the frame where the permanent magnet is placed. Then mark the holes printed on the
bottom box (see fig. 3), 5-6 mm drill with drill and secure the bottom (Fig. 3-4).
3) Remount the card, block with the screw, close JP1 and JP2 contacts (ready for “magnetic sensor
calibration” mode) and mount the battery and the plastic cover.
4) Place the permanent magnet on the mobile part of the fixture trying to match the reference marks in the
case of the sensor and permanent magnet. If the magnet is sufficiently close to the magnetic contact, LED
will switch on indicating the closure of the magnetic contact. However, the sensor will not be installed at a
distance greater than 30mm from the permanent magnet.
Learning procedure and radio test:
Prepare the receiver side in the learning mode.
Activate the "radio mode" of the MAG 4M 5026 by closing of JP1 contact and JP2 opening.
The radio transmitter will send a modulated signal for 30 seconds with radio code set by 9 vias dip-switch.
Note: The installation of MAG 4M 5026 metal frames can cause radio performance losses. For critical
installations it advices to test the quality of the radio signal received with a receiver with RSSI output(for
more details see Aurel wireless catalogue).
The technical features can be change without forecast. AUR°EL S.p.A doesn’t assume any responsibility for the demages due to the improper use.
AUR°EL S.p.A.
Via Foro dei Tigli, 4 - 47015 Modigliana (FC) – ITALY Rev.A 11.06.2014
Tel.: +390546941124 – Fax: +390546941660 Page 3 of
7
http://www.aurel.it
- email:
Preliminary
Fig.4
Typical installation
Fig.3 fori per montaggio a parete