4.2.5. Changing the forced pump operation mode
Press the "
B
" button under the temperature setting. The digits begin to
blink and indicate the value of the current setting (left indicator). When
the "
B
" button is pressed again, the right temperature indicator starts
blinking. Press the "
B
" button again in order to edit the hysteresis (
HI
)
value of the left indicator. Press the "
B
" one more time in order to set the
hysteresis (
HI
) value of the right indicator.
After you press the "
B
" button one more time, the value of 85°C will be
displayed in the temperature section and on the right side of the display
the symbol of forced pump operation ( ) will be shown. The "+" or "-"
button can be used to make the pump work in a continuous manner ( ) or
stop ( ) after the temperature of 85°C is exceeded. Also, the "+" or "-"
button can be used to set the maximum value, equal to 55°C, which, when
exceeded, will cause the CH pump to stop (e.g. in the case of floor
heating).
The operation of the valve or the second CH pump can be set in the same
manner. After the operation mode is set, it must be confirmed (within 10
seconds) by pressing the "
OK
" button. Otherwise, the changed setting
will not be saved and the controller will return to the previous setting.
^
^
^
4.2.6. Automatic operation
The controller starts or stops the pump and the valve depending on the
set temperature value. In the CH system, the pump and the valve are
started when the temperature in the location of the sensor exceeds the
set value and stopped when the temperature drops below the value set
in the controller, taking into account the hysteresis.
4.2.7. Tryb ręczny - praca ciągła
Step 1
–
I
n order to manually switch on the CH pump in the fireplace
circuit (regardless of the current temperature at the
SR2
sensor), press
the
"
B
"
button for 3 seconds. The display will show the hand symbol "
"
on the left side of the pictogram indicating operation of the CH pump in
the fireplace circuit.
Step 2
–
I
f you press the
"
B
"
button again for 3 seconds, the manual
mode "
" will be activated for the tee valve (or the second CH pump)
"
" (hand symbol on the right side).
S
3
–
"
B
"
Step 4
–
f you press the
"
B
"
button yet again for 3 seconds, the manual
mode "
" will be activated for the automatically reset valve (or the
second CH pump) in the fireplace circuit (right side).
[h]
tep
If you press the
button one more time for 3 seconds, the
manual mode "
" will be activated for the CH pump (left side).
I
4.3. Wiring diagram
An example wiring diagram. This is a simplified diagram that does not
contain all the elements necessary for proper operation of the system.
1
7
2
3
4
5
8
9
6
230V mains
power supply
0
I
A
B
C
D
SR1 SR2 SR3
OUT1
OUT2
OUT3
OUT4
OUT5
IN
1.
Boiler stove fireplace,
6.
Radiator,
2.
Cut-off valve,
7.
Compression vessel,
3.
Pump,
8.
Temperature sensor,
4.
Exchanger ,
9.
CH boiler.
5.
Automatically reset actuator
,
NOTE: When only the SR2 sensor is connected, the remaining functions
of the controller are inactive, i.e. there is no indication of operation of
CH pump and of the control of the pump in the HDW circuit, and the
blower is not controlled.