Rev. 2/13
AM12MF18-1
11
•
Remove drain plug by turning counterclockwise.
•
Allow tank to drain completely.
•
Replace drain plug and hand tighten turning clockwise.
CLEANING BASKET FILTER
•
Remove fill cap and remove basket filter.
•
Rinse debris from filter with running water.
•
Replace basket filter and fill cap.
CONDITIONING WATER TANK
Conditioning the water tank ensures that the cooling system will operate at optimal levels throughout the
life of the system. It is suggested that the tank be conditioned at an interval of every 4th filling or
once/month; whichever comes first.
•
Completely drain water tank. (See Emptying Water Tank)
•
Fill tank with CLEAN WATER. Be sure to always fill tank with basket filter in place.
•
Add
¼
teaspoon of unscented chlorine bleach to the water tank (approximately 5 drops per gallon of
clean water).
•
Replace cap and hand tighten.
•
Run system for 5 minutes with a WET mist.
•
The system is conditioned and ready for operation.
PROBLEM
CAUSE
CORRECTION
Fan not running
1. Power cord is not connected
2. Switch is in the “OFF” position
3. The indicator light on the GFCI
is out
1. Connect power cord
2. Switch fan on high, medium, or low
Positions
3. Press "RESET" button on the GFCI, if
the indicator light does not light up,
check whether the fuse needs to be
changed
Unit not misting
1. Misting switch is in off position
2. Water tank is empty
3. Mist control valve in
the ”CLOSED” position
4. Water filter could be clogged
5. Air tank leak
1. Turn misting switch on
2. Fill tank with clean water
3. Open valve (counter-clockwise)
4. Replace water filter
5. Tank fill cap is not tight
Water streaming
from nozzle
1. Air pump is not working
2. Air flow is low
1. Turn on the mist ON/OFF switch
2. Possible kinked air hose.
Check assembly to ensure hoses are
routed and installed correctly.
Change the intake filter of air pump.