Aura Magnetic Control 105DJ Series User Manual Download Page 6

INSTALLATION

Standard mounting parts are supplied with the package. The parts list 

below is used for mounting by the authorized service. All additional 

mounting parts are subject to additional fee.

1. Casting with clips

2. Casting nuts

3. Inner hanger

4. Outer hanger

5. Shower hose

6. Shower body

7. Filter (inlet)

8. Screw, dowel and crochet

MOUNTING OF DEVICE FOR OPEN OUTLET  

(MODEL 105DJ)

Mounting of Device 

to Shower and Parts 

to be used

   Mounting of Device to 

Main Pipe Line

• Water inlet and outlet of 

the device is R 1/2”.

• Connect the blue colour 

cold water inlet pipe to 

cold water pipe line with 

a flexible hose.

• Connect the red colour 

hot water outlet pipe to 

hot water pipe line with 

a flexible hose. 

CAUTION !

The water outlet must not be

connected to any tap/valve

or fitting other than those specified.

MOUNTING OF DEVICE FOR CLOSED 

OUTLET (MODEL 105DJ/C)

Summary of Contents for Magnetic Control 105DJ Series

Page 1: ...MODEL 105DJ 105DJC User Manual Water Heater...

Page 2: ...ase read the entire user manual thorough ly and keep it for future reference TECHNICAL SPECIFICATIONS Voltage 230 VAC Frequency 50 60 Hz Power 7 kW Inlet Controlled Pressure 0 Pa model 105DJ Outlet Co...

Page 3: ...rical devices with the power more than 1kW while your water heater is operating 9 This appliance is not intended for use by person including children with reduced physical sensory or mental capabiliti...

Page 4: ...isely detects the flow of water SAFETY THERMOSTAT It cuts electricity supply when the outlet water temperature is above 70 C The heater starts to operate again when this temperature drops below 60 C S...

Page 5: ...er heater and call the service CAUTION If E1 E2 E9 is shown in the display turn the water heater off and then on by using the ON OFF switch If the fault is not eliminated call the service 2 If the wat...

Page 6: ...nd crochet MOUNTING OF DEVICE FOR OPEN OUTLET MODEL 105DJ Mounting of Device to Shower and Parts to be used Mounting of Device to Main Pipe Line Water inlet and outlet of the device is R 1 2 Connect t...

Page 7: ...in the sealing gasket and it is mounted on the back cover The back cover is fixed on the wall at 4 points using dowels and screws The cable is fixed with a cable clamp and the end of the cable is scre...

Page 8: ...BOSB Mermerciler Sanayi Sitesi 7 Cadde No 14 34524 Beylikd z stanbul Turkey Tel 90 212 875 35 62 Fax 90 212 875 36 64 www iea com tr info iea com tr...