Aura ASR1203-OO Installation Manual Download Page 5

Installation Manual

ASR1203-OO *** Valve Rough-In

Dimensions of fixtures are approximate and may vary ± 6mm (1/4”). Structure measurements must be verified against the unit to ensure proper fit.

Product images and specifications are for illustrative purposes only, product design may vary.

5

1

2

3

1

2

3

Test the Handle/Valve:

 

Water temperature will decrease when you rotate 

clockwise, and water temperature will increase when you 

rotate counter clockwise.

CLEANING STOP FILTERS

Removing the stop filters:

 

Using a wrench, take out both of the 

Stops (1)

 by rotating 

them counter-clockwise.
Remove 

Filter (2)

 and 

Valve (3)

 and check for any debris 

or build up.
Use clean water to rinse and clean 

Filter (2)

.

Installing the stop filters:

  

Slide 

Filter (2)

 on to 

Valve (3)

. Then thread it to the valve 

body. 
Use a wrench to tighten the 

Stops (1)

 to the valve.

3A.

4A.

4B.

Thermostatic Valve Cover Plate and Handle Installation

)

Tempature Lock;

must be pushed.

3A.

4A.

4B.

CAUTION! 

If you need to adjust temperature more 

than 38°C (100°F), then you need to press 

the override button and rotate it counter 

clockwise. It should not be possible to turn 

the stem further counter-clockwise.

REQUIRED

REQUIRED

Testing Handles and Replacing and Cleaning Stop Filters

CAUTION! 

Please check that the marked line on 

the thermostatic cartridge points to the 

rectangle notch on the plastic parts, if not, 

please rotate the brass part. Then install 

the handle.

1

2

3

6

9

4

10

5

11

8

7

1

2C.

2D.

Thermo Cartridge Calibration Area

D2.

D3.

Marked Line & Groove

MUST ALIGN

1

2

TOP VIEW

(1)

(2)

Plastic Body

Boarch

Installing Cover Plate:

Carefully install the 

Trim Plate (1)

, make sure to keep the 

Trim Plate (1)

 tight against the wall.

Configuring the Cartridge:

Before installing the handle and the rest of the trim, 

ensure the thermo cartridge is positioned correctly. Verify 

that the line etched on the top of the 

Plastic Body (1)

 of 

the cartridge lines up exactly with the black line on the 

brass 

Boarch (2)

 as you are looking down on it.  

(See Figures D2. and D3. on the left)

Installing Volume Control Handle:

 

Install 

Plastic Washer (4)

 on diverter. Install the 

Volume 

Control Handle (1)

. Use the 

Allen Key (9)

 to tighten the 

Handle Set Screw (3)

, then insert 

Set Screw Cap (3)

.

Installing Thermostatic Handle:

 

Install 

Plastic Washer (5)

 on the thermostatic mixer. 

Install the 

Thermostatic Mixer Handle (6)

, so that the 

safety stop override button is at the 9:00 position. Use 

the 

Allen Key (9)

 tighten the 

Handle Set Screw (8)

, then 

insert 

Set Screw Cap (7)

.

2C.

2D.

2E.

Summary of Contents for ASR1203-OO

Page 1: ...e and may vary 6mm 1 4 Structure measurements must be verified against the unit to ensure proper fit PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 3 Way No Share Thermostatic Shower Valv...

Page 2: ...VENT DAMAGE Keep receipts proof of purchase and place of purchase for this product The receipt is required should it be necessary to request warranty parts MAINTENANCE CARE FOR YOUR AURA PRODUCTS To c...

Page 3: ...QTY 1 Protective Cover 1 2 Screw AP120 200 4 3 Valve Box 1 4 Hot Water Limiter AP120 204 1 5 Handle Extension AP120 201 1 6 Diverter Retaining Nut AP120 202 1 7 Diverter Cartridge AP120 111 1 8 Set S...

Page 4: ...Thermostatic Mixer Handle Cap Handle set Screw Volume Control Handle Plastic Washer Volume Control Escutcheon Plastic Washer Cap Handle Set Screw Allen Key Thermo Escutcheon Trim X X Diagram 1 ATTENTI...

Page 5: ...clockwise REQUIRED REQUIRED Testing Handles and Replacing and Cleaning Stop Filters CAUTION Please check that the marked line on the thermostatic cartridge points to the rectangle notch on the plastic...

Page 6: ...4 in to the valve Use a Allen key to tighten set Screw 5 Using a wrench screw on the Retaining Nut 3 clockwise Put on the Hot Water Limiter 2 Rotate Thermo Escutcheon 1 to the valve clockwise 5A 5B 6...

Page 7: ...es are approximate and may vary 6mm 1 4 Structure measurements must be verified against the unit to ensure proper fit Product images and specifications are for illustrative purposes only product desig...

Reviews: