Aumuller M-COM Assembly And Commissioning Instructions Download Page 1

!

!

M-COM (Main control unit)

24V

•  By  using  the 

M-COM

  6  single  actuators  (drives  or

  locks) are linked together in a multi-drive system.
•  Whithin  seconds,  the 

M-COM

  links  and  programmes

  the synchronized driverunnint mode and one sequentce
  control, if additional locks are involved.
  When using 2 locking drives, these run parallel.
•  There  is  no  more  factory  set  programmation  required.
  All opening and locking drives in the multi-drive system
  are blind supplied. Drives do not have specifi c markings,
  such as Master, Slave 1 , Slave 2, etc.
•  To allow assembly and installation work, each drive may
  be run individually  - i. e. one locking drive in test run

•  Confi guration  of  the  multi-drive  system  will  be  perfor-
  med only after the drive installation has been completed.
•  Commissioning  of  the  multi-drive  system  may  only  be
  carried out when the drives have been correctly installed
  and  the 

M-COM

  has  been  connected;  these  are  im-

  portant  prerequisites  in  order  to  minimize  possible
  damages / injuries caused by improper installation.
•  A  Reset  of  the  confi gured  multi-drive  system  may  be
  performed  at  any  time  using  „UniPC“.  Once  the  Reset
  has  been  performed,  single  operation  of  the  drives  is
  again possible.
• 

M-COM

 allows a smooth exchange of drives in need of

  repair within the multi-drive system.

Warranty  claims  require  proper  and  profes-
sional assembly, installation and maintenance 
in  accordance  with  national  regulations  and 
manufacturer‘s instructions as to drives.

The  safety  of  the  supplied  product  docu-
mentation are to be observed.

Strictly observe the information given in this 
and  in  the  instructions  for  installation  of
drives when mounting the 

M-COM

.

Details  can  be  found  on  our  website
               

www.aumueller-gmbh.de

Keep this instruction over the lifetime of the
product.

Assembly and Commissioning Instructions

M-COM

Rated voltage:   

 

     

24V DC +/- 20%, (max. 2 Vss)

Current consumption:       

<12 mA

Control type:  

 

 

     

S12

Protection rating:   

     

IP30 rubber envelope

Ambient temperature range:   min. - 5 °C ... + 70 °C

Dimensions:    

 

 

     

45 x 17 x 6 mm

Connection wire:  

 

     

3 wire 0,5 mm

2

 x 50 mm

Feature / Equipment:        

Printed circuit board with components and con-

    

 

 

 

 

 

     

nection wires to be installed in connection box to

    

 

 

 

 

 

     

be supplied on site.

Part.-No.:    

524177

Application

:  

Communication  module  for  automatic  confi guration  and

surveillance of max. 4 opening and 2 locking drives version S12 / S3 (software
version SW-V2) in synchronised multi-drive systems.