Auxiliary Power Supply
Water Pump Cable
DUST SUPPRESSION SYSTEM
Control Box
• Mount control box in a suitable position in the
operators area so that the toggle switch is
accessible.
• Route cable from pump along parent machine to
the control box in the operator’s area. Secure as
necessary, ensure cable is free from moving parts.
• Connect the cable plug to the control box plug.
• Connect the control box to the parent machines
auxiliary power supply.
• The water pump is switched on an off with the
toggle switch on the control box.
WARNING:
Do not run the pump without adequate water.
Water Tank
Fill water tank with clean fresh water do not use dirty water, salt water or chemicals. Dirty water can block
the system and spray nozzels. Salt water and chemicals will corrode the system. Chemical can also be
harmful to peaple , animals, plants and soil.
Water Pump
Water Tank
Filler Cap
Suction Filter
Floating Breather Valve
Spray Nozzles