COMpact 5000/R - Firmware V6.6A - Installation, Operation and Configuration V05 03/2016
79
Installation and Commissioning
Network Provider
Installing Cable between External Analogue Port and Analogue Connection
Note:
If the analogue connection is relatively far away from the PBX, a cable
with wall socket must first be laid.
•
The RJ-11/RJ-11 connection cable included in the scope of delivery of the COMpact 2FXO
module
•
In Germany, the RJ-11/TAE-F adapter included in the scope of delivery of the COMpact
2FXO module
1. Insert one end of the connection cable into the RJ-45 socket of the external analogue
port.
2. Proceed as follows:
•
In Germany: Insert the other end of the connection cable into the RJ-11 socket of
the adapter.
•
Outside Germany: Insert the other end of the connection cable into the RJ-11 wall
socket of the network provider.
3. Only in Germany: Insert the TAE-F plug of the adapter into the TAE-F wall socket of
the network provider.
Installing Cable between External Analogue Port and Analogue Connection
Requirements:
•
Inserted COMpact 2FXO module
•
Maximum distance/line length between socket and PBX, depending on the cable used (with
a pair diameter of 0.6 mm: approximately 800 m )
•
Installation cable (for example, J Y (St) Y 2 x 2 x 0.6) with the following characteristics:
–
4-core
Warning:
Voltages that run through the connection socket of the network
provider can cause life-threatening electric shocks.
•
Do not connect the PBX until the casing on the connection socket of the
network provider is closed again.