Technical data
200L
270 L
outer casing
plastic
insulating material
50 mm PU foam
nominal volume
200 L
270 L
tank material
stainless steel - K44 (food grade)
maximum service pressure
0,6 Mpa (6 bar)
dimensions
Ø 630 x h. 1470 mm
Ø 630 x h. 17480 mm
weight with packing
71,2 kg
80,7 kg
electrical supply
230 V - 50 Hz - 16A
protection rating
IPX1
maximum power
2200 w
D-curve circuit breaker
16 A
refrigerant
R 290 (propane) - 0,15 kg
heat pump maximum pressure
2,5 Mpa (25 bar)
water temperature with heat pump
60°C
air temperarture operating range
from - 7°C to + 35°C
noise level at speed 1 / speed 2 (1)
36 dB(A) at 2 meters
air flow
350 m3 / hour
maximum air duct length (Ø 160)
supple piping: 10 m / rigid piping: 20 m
air inlet and outlet diameter
160 mm
condensate flow
0,3 liter / hour
water connection diameter
3/4" (male)
condensate drainage pipe
18/23 mm
electric back-up (85°C safety cut-out)
1500w
max. water temp. with elec. back-up
65°C
heat pump max. input power - water at 60°C
700w
heat pump max. output power - water at 45°C
1650w
efficiency with outside air at + 7°C
water needs according to EN 16147 (cycle)
L
L
certified COP
3,21
3,1
input power to maintain water at 55°C (2)
0,024 kW
0,026 kW
reference temperature
53,46°C
54°C
heating time
6h13
10h30
hot water production within 8 hours
308 liters
348 liters
hot water production within 14 hours
643 liters
609 liters
efficiency with outside air at + 15°C
water needs according to EN 16147 (cycle)
L
L
certified COP
3,3
3,28
input power to maintain water at 55°C (2)
0,026 kW
0,028 kW
reference temperature
53,77°C
54,5°C
heating time
5h40
9h30
hot water production within 8 hours
310 liters
404,8 liters
hot water production within 14 hours
681 liters
708 liters
(1) with piping for air intake and air rejection