31
ca6552/6552sst. 2011 Audiovox Electronics Corporation. All rights reserved.
3 - Running Lights: Controls the WHITE parking light output wire during remote
start.
Steady - Parking lights constant during the remote start cycle.
Flashing - Parking lights flash at a slow pace during the remote start cycle.
4 - Tach Mode: Determines how the system monitors the engine running during
remote start.
Tach - Hard wired directly to the tach wire of the vehicle to monitor AC
voltage.
Tachless (Crank Average/Voltage) - Determines crank time by averaging the
last 8 times the vehicle was started with the key and then monitors the
change in voltage after remote start.
Hybrid (Crank Average / No Voltage) - Determines crank time by averaging
the last 8 times the vehicle was started with the key.
DBI Port - Monitors the vehicle’s tach rate through an interface module
connected to the DBI port.
5 - Voltage Level: The voltage variance for remote start when set to tachless.
(see tach mode)
HIGH - The variance in battery voltage from before the remote start
is activated to after the engine is running must be greater than 0.5 volts.
LOW - The variance in battery voltage from before the remote start
is activated to after the engine is running may be less than 0.5 volts.
6 - Crank Time: Preset output times for the PURPLE starter wire.
7 - Crank Average / Crank Time: The length of time in which the remote start
will crank the vehicle’s starter.
Crank Average - Determines crank time by averaging the last 8 times the
vehicle was started with the key.
Preset Time - Preset starter output time. (see crank time)