MODE SWITCH

To  the  right  of  the  Master  Level  controls  is  a  switch  labeled  “Mode”  with 
“Stereo” and “Bridged” as options. If you will be connecting one or two pair 
of speakers to the amplifier, place the switch in the “Stereo” position. 

NOTE:

  If  you  are  using  the  AMP200/300  in  stereo  mode,  with  2  sets  of 

speakers (A and B), make sure each speaker has an impedance of 8 ohms 
or greater.

When  used  in  “Bridged”  mode,  the  amplifier  is  a  single  channel  Mono 
amplifier. 

If you will be using a pair of channels to power a single mono speaker, place 
the switch in the “Bridged” position, and be sure to read the section titled 
“Speaker Terminals” below. 

For the amplifier to operate properly in bridged mode you should have both  
“Right  and  Left”  inputs  connected  to  the  amplifier.  The  amplifier  will  sum 
these signals and create your Mono source. 

NOTE: 

Both of the “Master Level” adjustments should should be set to the 

center, 12 o’clock position for normal amplifier operation in “Bridged” mode.

NOTE:

  The  AMP200  supplies  250W  in  bridged  mode,  while  the  AMP300 

supplies 470W in bridged mode. Please verify that your speakers are capable 
of handling such power to avoid possible damage!

SPEAKER TERMINALS

Terminals are provided for “A” and “B” pairs of speakers for each channel. If 
you will be using the amplifier as a stereo amplifier (i.e. not a bridged amplifier), 
connect the speaker’s positive (red) terminal to the amplifier’s positive (red) 
terminal, and the speaker’s negative (black) terminal to the amplifier’s negative 
(black) terminal (immediately beside the positive terminal).  

NOTE: 

Use the appropriate gauge speaker wire when connecting speakers 

to the AMP200/300.

If using one pair of channels bridged, place the “Mode” switch in the “Bridged” 
position and use both RED terminals to connect to the speaker. 

NOTE: 

When in “Bridged” mode make sure to connect the speaker’s negative 

(black) terminal to the amplifier’s positive (red) terminal of the right channel and 
the speaker’s positive (red) terminal to the amplifier’s positive (red) terminal of 
the left channel

 
NOTE: 

Only one pair of channels can be bridged together. Do not attempt to 

bridge both A & B speaker terminals, as this may result in a lower impedance 
than  the  amplifier  is  designed  to  accommodate  and  may  damage  your 
amplifier. The minimum impedance for the total load connected to a pair of 
channels in the bridged mode is 8 ohms.

MAINS POWER INLET/FUSE/

VOLTAGE SELECTOR

Power inlet accepts the IEC type linecord supplied with the amplifier.  Fuse 
in integrated holder provides safety protection from fault conditions: only 
replace fuse with one of same type and rating.

This amplifier is configured for operation at the mains voltage of the market 
in which it is sold.  

The AMP200/300 can be configured for operation from either  115V ~60Hz 
or 230V ~50Hz AC mains. Installed mains fuse  must be of type and rating 
marked on amplifier corresponding  to configured AC mains voltage.  

Should you wish to configure the AMP200/300 for use at the alternate AC 
mains voltage, please contact AudioSource support at 1.800.435.7115.

Figure 7. Mode Select Switch

Figure 8. Speaker Terminals

11

14

15

&

16

17

&

Summary of Contents for Amp 300

Page 1: ...product is damaged or missing please call your dealer or AudioSource directly at 1 800 435 7115 or 503 286 9300 Please read your warranty and retain your receipt and original carton for possible future use For more information about AudioSource electronics speakers and accessories please visit www audiosource net AMP200 AMP300 Home Audio Multi Zone Power Amplifier AudioSource 9300 North Decatur St ...

Page 2: ...cement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at the plugs convenience receptacles and at the point where they exit from the appliance 11 Only use attachments or accessories specified by the manufacturer 12 Unplug the apparatus during lightning storms or when unused for long periods of time 13 Refer all servicing to qualified personnel Servicing...

Page 3: ...y of the original sales invoice from an authorized AudioSource dealer when making a claim against this limited warranty This limited warranty only covers failures due to defects in materials or workmanship that occur during normal use It does not cover failures resulting from accident misuse abuse neglect mishandling misapplication alteration faulty installation modification service by anyone other...

Page 4: ...a source with speaker level output instead of line level outputs Use the Speaker Level Input Line Select to route the source to Line 1 or Line 2 8 Line 2 Input Output The primary line level input and output 9 Delay Time Allows for a 3 15 second delay to be set and accomodate the source connected to the Line 1 input 10 Master Level Controls Provides indepedent adjustment of Left and Right channel m...

Page 5: ...et the maximum level of the channel identified by the channel designator below it The volume range is labeled Minimum to Maximum Rotate the knob clockwise to increase output and counter clockwise to decrease output These adjustments set the master level and if not configured at initial setup of the AMP200 300 may adversely affect the performance of the amplifier Begin Master Level control setup by ad...

Page 6: ...red terminal to the amplifier s positive red terminal and the speaker s negative black terminal to the amplifier s negative black terminal immediately beside the positive terminal NOTE Use the appropriate gauge speaker wire when connecting speakers to the AMP200 300 If using one pair of channels bridged place the Mode switch in the Bridged position and use both RED terminals to connect to the speake...

Page 7: ...e the balance set to the center detent position SETUP FOR MULTIPLE SOURCE In the application shown in Figure 10 a distributed audio system is connected to the AMP200 300 as a local zone amplifier via the Line 2 inputs Normally the distributed audio system will be the audio source for the AMP200 300 The distributed audio is then passed on to be used by additional zones or sub zones in the distribute...

Page 8: ...100 0303B AMP 200 AMP300 OWNER S MANUAL Power Model AMP200 Stereo Power Amplifier Speakers A B ON OFF ON STANDBY Balance Trim Left Right Volume Trim Power Model AMP200 Stereo Power Amplifier Speakers A B ON OFF ON STANDBY Balance Trim Left Right Volume Trim 4 0 89mm 16 5 419mm 14 0 356mm 5 8 133mm 16 5 419mm 14 0 356mm AMP 300 SPECIFICATIONS Stereo 8 ohm 150W RMS per channel at 8 ohms 20Hz 20kHz 0...

Reviews: