MODE SWITCH

To  the  right  of  the  Master  Level  controls  is  a  switch  labeled  “Mode”  with 

“Stereo” and “Bridged” as options. If you will be connecting one or two pair 

of speakers to the amplifier, place the switch in the “Stereo” position. 

NOTE:  If  you  are  using  the  AMP210/310  in  stereo  mode,  with  2  sets  of 

speakers (A and B), make sure each speaker has an impedance of 8 ohms 

or greater.

When  used  in  “Bridged”  mode,  the  amplifier  is  a  single  channel  Mono 

amplifier. 

If you will be using a pair of channels to power a single mono speaker, place 

the switch in the “Bridged” position, and be sure to read the section titled 

“Speaker Terminals” below. 

While the amplifier operates in bridged mode you are required to have   

the Left  input  connected  to  the  amplifier  only.  The  amplifier  will  use  

this signal to create your Mono source. 

NOTE:  The  AMP210  supplies  250W  in  bridged  mode,  while  the  AMP310 

supplies 450W in bridged mode. Please verify that your speakers are capable 

of handling such power to avoid possible damage!

SPEAKER TERMINALS

Terminals are provided for “A” and “B” pairs of speakers for each channel. If 

you will be using the amplifier as a stereo amplifier (i.e. not a bridged amplifier), 

connect the speaker’s positive (red) terminal to the amplifier’s positive (red) 

terminal, and the speaker’s negative (black) terminal to the amplifier’s negative 

(black) terminal (immediately beside the positive terminal).  

NOTE: Use the appropriate gauge speaker wire when connecting speakers 

to the AMP210/310.

If using one pair of channels bridged, place the “Mode” switch in the “Bridged” 

position and use both RED terminals to connect to the speaker. 

When in “Bridged” mode make sure to connect the speaker’s negative 

(black) terminal to the amplifier’s positive (red) terminal of the left channel and 

the speaker’s positive (red) terminal to the amplifier’s positive (red) terminal of 

the right channel.

 

NOTE: Only one pair of channels can be bridged together. Do not attempt to 

bridge both A & B speaker terminals, as this may result in a lower impedance 

than  the  amplifier  is  designed  to  accommodate  and  may  damage  your 

amplifier. The minimum impedance for the total load connected to a pair of 

channels in the bridged mode is 8 ohms.

MAINS POWER INLET/FUSE/

VOLTAGE SELECTOR

Power inlet accepts the IEC type line cord supplied with the amplifier. A fuse

in the integrated holder provides safety protection from fault conditions: 

replace fuse with one of same type and rating only.

This amplifier is configured for operation at 115V. (North America) 

The AMP210/310 can be configured for operation from either  115V ~60Hz 

or 230V ~50Hz AC mains. Installed mains fuse  must be of type and rating 

marked on amplifier corresponding  to configured AC mains voltage.  

Should you wish to configure the AMP210/310 for use at 230V ~50Hz  

please contact your dealer or distributor. 

Figure 8. Mode Select Switch

Figure 10. Speaker Terminals

12

15

16

&

17

18

&

Mode

Stereo Bridged

Speaker A

R

L

R

L

-

-

-

+

+

+

-

-

+

+

Bridge

Speaker B

LIGHT BAR DISPLAY

19

On   Off

Light Bar Display

This switch controls the lighted bars on the front of the amplifier. These bars

light red when the amplifier is in operation. If the amplifier is visible, and a low

light setting is desired, use this switch to turn off the light bars. The other LED 

indicators on the front panel as well as the power button lighted ring are not 

affected by this control.

 

Figure 9. Light Bar Display Control 

Summary of Contents for AMP 210

Page 1: ...ible future use For more information about AudioSource electronics speakers and accessories please visit www audiosource net AMP210 AMP310 Home Audio Multi Zone Power Ampli er AudioSource 9200 North D...

Page 2: ...tect the power cord from being walked on or pinched particularly at the plugs convenience receptacles and at the point where they exit from the appliance 11 Only use attachments or accessories speci e...

Page 3: ...n authorized AudioSource dealer when making a claim against this limited warranty This limited warranty only covers failures due to defects in materials or workmanship that occur during normal use It...

Page 4: ...er on other electronics via a 3 5mm mini phone plug cable 14 Power Mode Sets the power on option of the AMP210 310 Set it to Normal for manual power on off Set to Auto On for signal sensing Set to Tri...

Page 5: ...annel identi ed by the channel designator below it The volume range is labeled Minimum to Maximum Rotate the knob clockwise to increase output and counter clockwise to decrease output These adjustment...

Page 6: ...in the Bridged position and use both RED terminals to connect to the speaker When in Bridged mode make sure to connect the speaker s negative black terminal to the ampli er s positive red terminal of...

Page 7: ...he distributed audio system will be the audio source for the AMP210 310 The distributed audio is then passed on to be used by additional zones or sub zones in the distributed system via the Line 2 out...

Page 8: ...NER S MANUAL 3 8 96 5mm 16 5 419mm 13 75 349mm 5 5 140mm 16 5 419mm AMP310 SPECIFICATIONS Stereo 8 ohm 150W RMS per channel at 8 ohms 20Hz 20kHz 0 1 THD N Stereo 4 ohm 225W per channel at 4 ohms 20Hz...