Specifications
Height / Width / Depth:
45 mm / 215 mm / 220 mm
Weight:
1.78 kg
Power supply:
110 - 250 Vac, ~ 50 / 60 Hz
Passive protection:
Fuse 6.3 A T, not accessible
Maximum area:
360 m² according to IEC 60118-4
Maximum input power:
< = 314 VA
Loop output
Max. current:
2x 5,8 A RMS
Max. tension:
2x 48 V peak
Connector:
2x Neutrik NL4 speakON-sockets, layout 1+/1-
Frequency range:
100-5000 Hz ( ± 3 dB)
Distortion:
< 1% at rated power output, 1 kHz
INPUT 1 and 2:
0,5 mV to 100 mV / 10 kOhm (MIC)
or 25 mV to 4 V / 10 kOhm (LINE)
Combo-XLR-3 socket (INPUT 1)
Phoenix contact (INPUT 2)
12V toggable phantom power
INPUT 3:
100V-Input for connecting PA-systems
Automatic Gain Control (AGC)
Dynamics: up to 36dB
Environmental working range:
0°C - 45°C, up to 2000 metres MASL
Power consumption during idle:
15,5 W,at 230V AC, 2 connected 1 Ω- loops, at room
temperature after 30 min. stabilizing time
Max. power consumption:
50 W
This device complies with the following EC directives:
-
2017 / 2102 / EC RoHS-directive
-
2012 / 19 / EC WEEE-directive
-
2014 / 35 / EC Low voltage directive
-
2014 / 30 / EC Electromagnetic Compatibility
Compliance with the directives listed above is confirmed by the CE seal on the device.