Mains supply and safety
Mains Supply:
The mains voltage of Audiolab units is shown on the rear
panel. If this does not match the voltage in your area, consult your dealer.
The mains supply fuse is on the rear panel. If it has broken, check for any
obvious cause before replacing the fuse with one of the correct rating and
type. The fuses for all areas are type T (time lag ) AL 20mm.
The fuse values are:
8000Q: 220-240V:
1.0A
100-120V
: 1.6A
8000M: 220-240V:
3.15A
100-120V
: 5.0A
8000P:
220-240V: 4
.0A
100-120V
: 5.0A
The fuse is located in a slide-in
carrier which also contains a spare
fuse. The carrier can only be pulled
out after the IEC power cord is
unplugged. When the carrier is
opened the first fuse is the spare.
Remove and safely dispose of the
blown fuse before replacing it.
Class II construction double insulated. These products must not
be connected to earth.
Power Cord:
An AC power cord is normally supplied with a mains plug
suitable for your area. If you have any doubts, consult your dealer about
obtaining a suitable power cord.
Important notice to UK users
The appliance cord is terminated with a UK approved mains plug fitted
with a 5A fuse. If the fuse needs to be replaced, an ASTA or BSI approved
BS1362 fuse rated at 5A must be used. If you need to change the mains
plug, remove the fuse and dispose of this plug safely immediately
after
cutting it from the cord.
Connecting a Mains Plug
The wires in the mains lead are coloured in accordance with the code:
Blue: NEUTRAL; Brown: LIVE:
As these colours may not correspond to the coloured markings identifying
the terminals in your plug, proceed as follows:
The BLUE wire must be connected
to the terminal marked with the
letter N or coloured BLUE or
BLACK. The BROWN wire must be
connected to the terminal marked
with the letter L or coloured
BROWN or RED.
5A FUSE
BS 1362
BROWN
(Live)
BLUE
(Neutral)
Fuse Carrier
IEC Mains Connector
Use only attachments/accessories specified by the manufacturer.
Use only with a cart, stand, tripod, bracket, or table
specified by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the
cart/apparatus combination to avoid injury from tip-over.
Unplug this apparatus during lightning storms or when unused for long
periods of time.
Refer all servicing to qualified service personnel. Servicing is required
when the apparatus has been damaged in any way, such as power-
supply cord or plug is damaged, liquid has been spilled or objects have
fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
Warning:
To reduce the risk of fire or electrical shock, do not expose this
product to rain or moisture. The product must not be exposed to dripping
and splashing and no object filled with liquids such as a vase of flowers
should be placed on the product.
No naked flame sources such as candles should be placed on the
R
ead these instructions.
product.
Keep these instructions. In the event that you pass the product to a third
Caution:
Changes or modifications not expressly approved by the
party this instruction manual should be provided along with the product.
manufacturer could void the user's authority to operate this device.
Heed all warnings.
8000Q
: This equipment has been tested and found to comply with the
Follow all instructions.
limits for a Class B digital device, pursuant to part 15 of the FCC rules.
Do not use this apparatus near water.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
Clean only with dry cloth.
generates, uses and can radiate radio frequency energy and, if not
Do not block any ventilation openings.
installed and used in accordance with the instructions, may cause
Install in accordance with the manufacturer's instructions.
harmful interference to radio or television reception, which can be
Do not install near any heat sources such as radiators, heat registers,
determined by tuning the equipment off and on, the user is encouraged to
stoves, or other apparatus (including amplifiers) that produce heat.
try to correct the interference by one or more of the following measures:
Do not defeat the safety purpose of the polarized or grounding type plug.
Re-orientate or re-locate the receiving antenna. Increase the separation
A polarized plug has two blades with one wider than the other. A
between the equipment and the receiver. Connect the equipment into an
grounding type plug has two blades and a third grounding prong. The
outlet on a circuit different from that to which the receiver is connected.
wider blade or the third prong are provided for your safety. If the provided
Consult the dealer or an experienced radio/TV technician for help.
plug does not fit into your outlet, consult an electrician for replacement of
the obsolete outlet.
Important Note:
The batteries supplied with the 8000Q handset should
be treated with care and not punctured or damaged. Used batteries
Protect the power cord from being walked on or pinched, particularly at
should be disposed of in full conformity with recycling regulations in your
plugs, convenience receptacles, and the point where they exit from the
area. NEVER dispose of batteries in a fire or in the general rubbish.
apparatus.
CAUTION!
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ADVERTISSEMENT: RISQUE DE CHOC ELECTRIQUE-
NE PAS OUVRIR
TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER
NO USER-REMOVEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED PERSONNEL
This symbol indicates that there are important
operating and maintenance instructions in the
literature accompanying this unit.
This symbol indicates that dangerous voltage
constituting a risk of electric shock is present
within this unit.
1: Statutory & Safety Information
8000Q Pre-amplifier
8000P Power Amplifier
Inputs: Gain and Sensitivity
Rated Output Power
CD, TUNER, AUX, VIDEO, TAPE 1, TAPE 2: IMPEDANCE: 20k
W
100W (20dBW) /Channel into 8
W
both channels driven
GAIN: Adjustable by 3dB steps 0 -15dB., corresponding to
Input
SENSITIVITY(nom.): 100, 140mV, 200mV, 283mV, 400mV, 562mV
1V rms for 100W into 8
W
HEADPHONES: Gain adjustable 18dB - 33dB in 3dB steps
Input Impedance: 50k
W
(IHF, rel. 0.5V output)
Load
Signal To Noise Ratio
Any input, any gain setting: 97dB
Connected in parallel with INPUT
Headphones: 80dB
Gain
29.0 dB at1kHz
Frequency Response
10 Hz-20 kHz ±0.2 dB: 1 Hz-75 kHz -3 dB.
Signal To Noise Ratio
(IHF, rel. 0.dBW)
Total Harmonic Distortion & Noise
Better than 95 dB
Less than 0.007 % ref 7.7V rms, 20Hz - 20kHz
Frequency Response
Channel Balance
20 Hz-20 kHz ±0.3 dB
0.1 Hz-75 kHz -3 dB.
Within 1 dB
Total Harmonic Distortion & Noise
Channel Separation
Less than 0.05 %
Better than100 dB @ 1 kHz any input, any setting
Channel Balance
Pre-amp Output
Within 1 dB
Max. Output >7.7 V RMS (20dBm); Output impedance 75
W
Polarity (Phase)
Headphone Output
Non-Inverting
>7.7Vrms;100
W:
(for headphones 8
W
-2 k
W
impedance)
Muting
Record Output
Muting controlled automatically
VIDEO OUT, TAPE 1 OUT, TAPE 2 OUT: Gain 0 dB (x1); 100
W
Operating Temperature Range
Muting
10-35 °C
Attenuation>63 dB, controlled automatically
Power Requirements
(Depending on Region)
Operating Temperature Range
50-60 Hz 100V, 110-120V, and 220-240V models available
10-35 °C
Maximum Power Consumption: 500 VA
Power Requirements
(Depending on Region)
Dimensions
(WXHXD)
50-60Hz 100V, 110-120V, and 220-240V models available
445x74x337 mm - including feet, terminals and controls
Maximum Power Consumption: 15 VA
445 x 64 x 302 mm- excluding feet, terminals and controls
Dimensions
(WXHXD)
Weight
445x74x335 mm - including feet, terminals and controls
Net: 8.7 kg Shipping:10 kg
445 x 64 x 302 mm- excluding feet, terminals and controls
Weight
Net: 6 kg Shipping:7.3 kg
7: Specifications
8000M Power Amplifier
Rated Output Power
125W (21dBW) /Channel into 8
W
, 20Hz - 20kHz
Input Sensitivity
1.12V rms for 120W into 8
W
Input Impedance: 50k
W
Load
Connected in parallel with INPUT
Gain
29.0 dB at1kHz
Signal To Noise Ratio
(IHF, rel. 0.dBW)
Better than 96 dB
Frequency Response
20 Hz-20 kHz ±0.3 dB
0.1 Hz-75 kHz -3 dB.
Total Harmonic Distortion & Noise
Less than 0.05 %
Polarity (Phase)
Non-Inverting
Muting
Muting controlled automatically
Operating Temperature Range
10-35 °C
Power Requirements
(Depending on Region)
50-60Hz 100V, 110-120V, and 220-240V models available
Maximum Power Consumption: 300 VA
Dimensions
(WXHXD)
445x74x337 mm - including feet, terminals and controls
445 x 64 x 302 mm- excluding feet, terminals and controls
Weight
Net: 8.2 kg Shipping:9.6 kg
Audiolab reserves the right to alter design and specification without notice.