background image

This label tells you that the unit contains a Laser component. Opening the unit will expose the user to 
radiation from the laser beam.

Mains supply and safety

Mains Supply:

 The mains operating voltage of all Audiolab units is shown on the rear panel. If this 

does not match the voltage in your area, consult your dealer.

The mains supply fuse is located on the rear panel of the unit. If it has broken, check for any obvious 
cause before replacing the fuse with one of the correct rating and type. The fuse values are:

220 - 240V (UK, Korea, etc.)

T 1AL  20mm  Slow Blow

100 - 120V (USA, Japan, etc)

T 1.6AL  20mm  Slow Blow

The fuse is located in a slide-in carrier which also contains a 
spare fuse. The fuse carrier can only be pulled out after the 
IEC power cord is unplugged. When the carrier is opened the 
first fuse to be seen is the spare fuse. Remove and safely 
dispose of the fuse with the blown link before replacing it.

Power Cord: 

 An AC power cord is normally supplied with a 

mains plug suitable for your area. If you have any doubts, 
consult your dealer about obtaining a suitable power cord.

Class II construction double insulated. This product must not be connected to earth.

Important notice to UK users

The appliance cord is terminated with a UK approved mains plug fitted with a  A fuse. If 

3

the fuse 

needs to be replaced, an ASTA or BSI approved BS1362 fuse rated at 5A must be used. If you need to 
change the mains plug, remove the fuse and dispose of this plug safely immediately

 

after cutting it 

from the cord.

Connecting a Mains Plug 

The wires in the mains lead are coloured in accordance with the 
code: Blue: NEUTRAL;  Brown: LIVE:  As these colours may not 
correspond to the coloured markings identifying the terminals 
in  your  plug,  proceed  as  follows:  The  BLUE  wire  must  be 
connected to the terminal marked with the letter N or coloured 
BLUE or BLACK. The BROWN wire must be connected to the 
terminal marked with the letter L or coloured BROWN or RED. 

Use only attachments/accessories specified by the manufacturer.

Use  only  with  a  cart,  stand,  tripod,  bracket,  or  table 
specified by the manufacturer, or sold with the apparatus. 
When  a  cart  is  used,  use  caution  when  moving  the 
cart/apparatus combination to avoid injury from tip-over.

Unplug this apparatus during lightning storms or when unused for long 
periods of time.
Refer all servicing to qualified service personnel. Servicing is required 
when the apparatus has been damaged in any way, such as power-
supply cord or plug is damaged, liquid has been spilled or objects have 
fallen into the apparatus, the apparatus has been exposed to rain or 
moisture, does not operate normally, or has been dropped.

Warning:

 To reduce the risk of fire or electrical shock, do not expose this 

product to rain or moisture. The product must not be exposed to dripping 
and splashing and no object filled with liquids  such as a vase of flowers  
should be placed on the product.
No naked flame sources such as candles should be placed on the product.

R

ead these instructions. 

Caution:

  Changes  or  modifications  not  expressly  approved  by  the 

Keep these instructions. In the event that you pass the product to a third 

manufacturer could void the user's authority to operate this device.

party this instruction manual should be provided along with the product.

This equipment has been tested and found to comply with the limits for a 

Heed all warnings. 

Class B digitial device, pursuant to part 15 of the FCC rules. These limits 

Follow all instructions. 

are  designed  to  provide  reasonable  protection  against  harmful 

Do not use this apparatus near water. 

interference in a residential installation. This equipment generates, uses 

Clean only with dry cloth. 

and can radiate radio frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful interference to radio 

Do not block any ventilation openings. 

or television reception, which can be determined by tuning the equipment 

Install in accordance with the manufacturer's instructions. 

off and on, the user is encouraged to try to correct the interference by one 

Do not install near any heat sources such as radiators, heat registers, 

or more of the following measures: 

stoves, or other apparatus (including amplifiers) that produce heat. 

Re-orientate or re-locate the receiving antenna. Increase the separation 

Do not defeat the safety purpose of the polarized or grounding type plug. 

between the equipment and the receiver. Connect the equipment into an 

A  polarized  plug  has  two  blades  with  one  wider  than  the  other.  A 

outlet on a circuit different from that to which the receiver is connected. 

grounding type plug has two blades and a third grounding prong. The 

Consult the dealer or an experienced radio/TV technician for help.

wider blade or the third prong are provided for your safety. If the provided 
plug does not fit into your outlet, consult an electrician for replacement of 

Important Note: 

The batteries supplied with this unit should be treated 

the obsolete outlet. 

with  care  and  not  punctured  or  damaged.  Used  batteries  should  be 

Protect the power cord from being walked on or pinched, particularly at 

disposed of in full conformity with recycling regulations in your area. 

plugs, convenience receptacles, and the point where they exit from the 

NEVER dispose of batteries in a fire or in the general rubbish.

apparatus. 

CAUTION!

RISK OF ELECTRIC SHOCK

DO NOT OPEN

ADVERTISSEMENT: RISQUE DE CHOC ELECTRIQUE-

NE PAS OUVRIR

TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER

NO USER-REMOVEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED PERSONNEL

This  symbol  indicates  that  there  are  important 
operating  and  maintenance  instructions  in  the 
literature accompanying this unit. 

This  symbol  indicates  that  dangerous  voltage 
constituting  a  risk  of  electric  shock  is  present 
within this unit. 

1: Statutory & Safety Information

Analogue Specifications

Digital Specifications

General Specifications

Connectors: 

DAC:

Operating Temperature Range:

2 pairs RCA phono

24bit 192kHz, 5th order Sigma Delta

10ºC-40 °C (ambient)

Output Level:

Output Format: 

Power Requirements:

 

(Depending on Region)

2.4V rms

SPDIF

50-60Hz 100 V, 110-120 V, and 220-240 V models available

Frequency Response: 

Connectors: 

Power Consumption: 

20Hz-20Khz +/- 0.5dB

75ohm BNC, RCA phono, Optical

Less than 25W

Output Impedance:

Output Level:

Dimensions (W x H x D):

100 Ohms

 550mV p-p ( nom.) ±10%

445 x 74 x 335 mm - including feet, terminals and controls

S/N Ratio:

Output Impedance: 

Weight

Better than 100dBA

75 Ohms ±5%

Net: 6 kg
Shipping: 7.4 kg

Channel Balance: 

Colour:

Better than  ± 0.5dB @ 1 kHz

Silver

Channel Separation:

Accessories Supplied:

Better than 100dB @ 1 kHz

AC Power Cord

THD+N (at 1kHz): 

Analogue Stereo RCA 2 Phono-2Phono interconnect

Less than 0.003% 20Hz-20Khz 

Instruction Manual

(>-90dB/2.4V)

8000RC Remote Control with 2 x AA batteries

Audiolab reserves the right to alter design and specification 
without notice.
Specification may vary for different countries.
Audiolab is a member of the International Audio Group.

 

3A FUSE

BS 1362

BROWN

(Live)

BLUE

(Neutral)

Fuse Carrier

IEC Mains Connector

6: Specifications 8000CD

Reviews: