6.12.3 Metering Tone Parameters
The metering tone parameters are described in the table below.
Table
6-47: Metering Tone Parameters
Parameter
Description
Web: Generate Metering
Tones
EMS: Metering Mode
[PayPhoneMeteringMode]
Determines the method used to configure the metering tones that are
generated to the Tel side.
[0]
Disable = Metering tones aren't generated (default).
[1]
Internal Table = Metering tones are generated according to the
internal table configured by the parameter ChargeCode.
Notes:
This parameter is applicable only to FXS interfaces.
If you select 'Internal Table', you must configure the 'Charge Codes
Table' (refer to ''Configuring the Charge Codes Table'' on page
Web: Metering Tone Type
EMS: Metering Type
[MeteringType]
Defines the metering tone (12 or 16 kHz) that is generated by FXS
interfaces.
[0]
12 kHz = 12-kHz metering tone (default).
[1]
16 kHz = 16-kHz metering tone.
Notes:
A suitable (12 or 16 KHz) FXS Coefficient file must be used for
FXS interfaces.
For this parameter to take effect, a device reset is required.
Web: Charge Codes Table
EMS: Telephony FXS And FXO (SIP) Parameters Provisioning > Charge Codes
[ChargeCode]
This
ini
file table parameter configures metering tones (and their time
intervals) that the device's FXS interface generates to the Tel side.
The format of this parameter is as follows:
[ChargeCode]
FORMAT ChargeCode_
Index
= ChargeCode_
EndTime1
,
ChargeCode_
PulseInterval1
, ChargeCode_
PulsesOnAnswer1
,
ChargeCode_
EndTime2
, ChargeCode_
PulseInterval2
,
ChargeCode
_PulsesOnAnswer2
, ChargeCode_
EndTime3
,
ChargeCode_
PulseInterval3
, ChargeCode_
PulsesOnAnswer3
,
ChargeCode_
EndTime4
, ChargeCode_
PulseInterval4
,
ChargeCode_
PulsesOnAnswer4
;
[\ChargeCode]
Where,
EndTime = Period (1 - 4) end time.
PulseInterval = Period (1 - 4) pulse interval.
PulsesOnAnswer = Period (1 - 4) pulses on answer.
For example:
ChargeCode 1 = 7,30,1,14,20,2,20,15,1,0,60,1;
ChargeCode 2 = 5,60,1,14,20,1,0,60,1;
ChargeCode 3 = 0,60,1;
ChargeCode 0 = 6, 3, 1, 12, 2, 1, 18, 5, 2, 0, 2, 1;
Summary of Contents for mediapack MP-500
Page 1: ...Document LTRT 12801 October 2009 User s Manual Version 5 8...
Page 2: ......
Page 22: ...SIP User s Manual 22 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Page 24: ...SIP User s Manual 24 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Page 290: ...SIP User s Manual 290 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Page 440: ...SIP User s Manual 440 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Page 564: ...SIP User s Manual 564 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Page 566: ...SIP User s Manual 566 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Page 573: ...Version 5 8 573 October 2009 SIP User s Manual 13 Technical Specifications Reader s Notes...
Page 574: ...User s Manual Version 5 8 www audiocodes com...