AudioCodes MediaPack 20 Series Quick Setup Manual Download Page 3

 

|

 

P a g e

 

 

 

Front-Panel Description 

 

 

 

[

Number of PHONE LEDs and Presence of USB LED Depend on MP-20x Model

 

PHONE 

LED indicating FXS port (phone) status: 

 

 

  Green Slow-Flashing 

 

SIP user account for the analog line has been successfully 

registered to a proxy server

 

 

Phone is in on-hook state

 

 

 

  Green On 

Phone is in off-hook state 

 

 

  Green Fast-Flashing  Phone is ringing 

 

 

  Red On  

SIP user account registration failure for the analog line 

 

 

 

  Off 

No SIP user account has been configured for this analog line 

 

 

 

 

 

2 / 3  LAN / WAN 

LED indicating LAN and WAN status: 

 

 

  Green On 

Ethernet link is connected: 

 

100 Mbps: MP-202B/2S/SIP 

 

1000 Mbps: MP-204B/4S/SIP, MP-202R/2S/SIP/CER/R, and MP-

204R/4S/SIP/CER/R 

 

 

  Green Flashing 

Ethernet link is active (data is received or transmitted): 

 

100 Mbps:

 

MP-202B/2S/SIP 

 

1000 Mbps: MP-204B/4S/SIP, MP-202R/2S/SIP/CER/R, and MP-

204R/4S/SIP/CER/R  

 

 

  Yellow On 

Ethernet link is connected: 

 

10 Mbps: MP-202B/2S/SIP 

 

100 Mbps: MP-204B/4S/SIP, MP-202R/2S/SIP/CER/R, and MP-

204R/4S/SIP/CER/R 

 

 

  Yellow Slow-Flashing  Ethernet link is active (data is received or transmitted): 

 

10 Mbps: MP-202B/2S/SIP 

 

100 Mbps:

 

MP-204B/4S/SIP, MP-202R/2S/SIP/CER/R, and MP-

204R/4S/SIP/CER/R 

 

 

  Yellow Fast-Flashing  10-Mbps Ethernet link is active (MP-204B/4S/SIP, MP-

202R/2S/SIP/CER/R, and MP-204R/4S/SIP/CER/R) 

 

 

 Off 

No Ethernet link 

 

USB 

LED indicating USB port status:

 

 

 

  Green On 

USB device connected to USB port

 

 

 

  Off 

No USB device connected 

 

 

 

 

Summary of Contents for MediaPack 20 Series

Page 1: ...p instructions for cabling the device and for connecting it to the Internet Before you begin please read the Safety Precautions on page 7 Package Contents Make sure that the following items in addition to any separate orderable items that you may have purchased are included with your shipped device 1 x 12V AC power adapter 1 x RJ 11 telephone cable 1 x RJ 45 Ethernet cable Regulatory Information d...

Page 2: ...device Note The USB port is available only on these MP 20x models MP 204B 4S SIP MP 202R 2S SIP CER R and MP 204R 4S SIP CER R 4 WAN WAN Ethernet port interface RJ 45 for connecting to the WAN Note The Ethernet port speed depends on the MP 20x model Fast Ethernet 100Base T MP 202B 2S SIP Gigabit Ethernet 10 100 1000Base T MP 204B 4S SIP MP 202R 2S SIP CER R and MP 204R 4S SIP CER R 5 LAN PC LAN Et...

Page 3: ... 1000 Mbps MP 204B 4S SIP MP 202R 2S SIP CER R and MP 204R 4S SIP CER R Green Flashing Ethernet link is active data is received or transmitted 100 Mbps MP 202B 2S SIP 1000 Mbps MP 204B 4S SIP MP 202R 2S SIP CER R and MP 204R 4S SIP CER R Yellow On Ethernet link is connected 10 Mbps MP 202B 2S SIP 100 Mbps MP 204B 4S SIP MP 202R 2S SIP CER R and MP 204R 4S SIP CER R Yellow Slow Flashing Ethernet li...

Page 4: ...Internet router using an RJ 45 Ethernet cable 2 Connect the device s Ethernet port labeled LAN PC to your computer using an RJ 45 Ethernet cable 3 Connect the device s telephone ports labeled PHONE to your analog telephones or faxes using RJ 11 telephone cables 4 Optional For primary or secondary backup WAN connect a 3G 4G cellular modem dongle to the USB port labeled USB 5 Connect the device to a...

Page 5: ...red to obtain an IP address automatically The device has an embedded DHCP server which allocates a DHCP pool of IP addresses in the 192 168 2 0 24 subnet 2 Open a standard Web browser on your computer and then in the URL field enter the device s default IP address of 192 168 2 1 the Login screen appears 3 Enter the default case sensitive username admin and password admin and then click Continue th...

Page 6: ...he WAN Ethernet line Obtaining Software and Documentation If you have a maintenance and support agreement with AudioCodes or with an authorized AudioCodes Service Partner you can download the device s latest software version from AudioCodes Services Portal at https services audiocodes com registered users only To download the device s technical documentation such as the User s Manual from AudioCod...

Page 7: ...e that sufficient clearance from the top and sides are maintained to ensure proper airflow to avoid over heating of internal components Operate the device in an ambient temperature Tma that does not exceed 40 C 104 F Use only the supplied AC DC power adapter for connection to the power source In case of a malfunction do not attempt to fix the power adapter and do not use any other type of power ad...

Page 8: ...en Street Airport City Lod 7019900 Israel Tel 972 3 976 4000 Fax 972 3 976 4040 AudioCodes Inc 200 Cottontail Lane Suite A101E Somerset NJ 08873 Tel 1 732 469 0880 Fax 1 732 469 2298 Contact us https www audiocodes com corporate offices worldwide Website https www audiocodes com 2019 AudioCodes Ltd All rights reserved AudioCodes AC HD VoIP HD VoIP Sounds Better IPmedia Mediant MediaPack What s Ins...

Reviews: