Installation & Operation Manual
490
Document # LTRT-92224
Mediant 8000
15.
On the Mediant 8000, verify that the
Operational State
of all configured entities
(i.e. SS7 Node, SS7 Linkset, SS7 Routeset, SS7 Data Link, UAL Group and
E1/T1 Trunk) is
Enabled
.
Table
38-12: MTP3 Group Properties
Parameter Name
Type
Provisioning
Type
Description
Mtp3 Group
Name
String
Up to 20 chars.
Instant
The textual, user-defined name for the SS7
MTP3 Group, enabling it to be identified
intuitively and easily.
Redundancy
Mode
Enum
none, dualCpu
Online
Defines the Redundancy mode.
For a simple configuration, where only one
Media Gateway board is associated with
the MTP3 Group, define the Redundancy
Mode as none. In this configuration, the
MTP3/M3UA application does not survive
the Media Gateway boards' switchover (All
MTP3 entities go out of service.)
For a redundant MTP3 configuration,
where two Media Gateway boards are
associated with the same MTP3 Group
and
signaling node
is distributed
across both boards, define the
Redundancy Mode as
dualCpu
. In this
configuration the MTP3/M3UA
application is preserved during Media
Gateway boards'
switchover/switchback.
Summary of Contents for Mediant 8000
Page 2: ......
Page 33: ...Part I Hardware Overview This part describes the hardware overview of the Mediant 8000 chassis...
Page 34: ......
Page 90: ......
Page 158: ......
Page 264: ......
Page 546: ......
Page 775: ...Part VI Maintenance This part describes the Mediant 8000 maintenance procedures...
Page 776: ......
Page 834: ......
Page 879: ...Part VIII Appendices This part describes additional Mediant 8000 configuration procedures...
Page 880: ......
Page 924: ...Media Gateway Mediant 8000 www audiocodes com Installation Operation Maintenance Manual...