CHAPTER 5 Cabling the Device
Mediant 500 Gateway & E-SBC | Hardware Installation Manual
Connecting to the Power Supply
The device receives power from a standard alternating current (AC) electrical outlet. The
connection is made using the supplied AC power cord.
Table 5-3:
Power Specifications
Physical Specification
Value
Input Voltage
Single universal AC power supply 100 to 240V
AC Input Frequency
50 to 60 Hz
AC Input Current
0.8A
Max. Power Consumption
20W
●
The device must be connected to a socket-outlet providing a protective earthing
connection.
●
Use only the AC power cord that is supplied with the device.
ご注 意
本 製 品 に添 付 の電 源 ケーブルは、
Mediant 500 E-SBC
に専 用 設 計 されているため、汎
用 性 がありません
.
本 電 源 ケーブルを他 の機 器 に使 用 されないよう、ご注 意 ください
.
➢
To connect the device to the power supply:
1.
Connect the line socket of the AC power cord (supplied) to the device's AC power socket
(labeled 100-240V~50-60 Hz 0.8A), located on the rear panel.
Figure 5-8:
Connecting to the Power Supply
2.
Connect the plug at the other end of the AC power cord to a standard electrical outlet.
3.
Press the power switch to on (
I
) position so that the device receives power; the
POWER
LED
on the front panel is lit green (for more information, see
- 18 -