Installation & Maintenance Manual
6. Cabling the Mediant 1000B PSTN Gateway
Version 6.8
39
Microsoft Lync Server
6
Cabling the Mediant 1000B PSTN Gateway
This section describes how to cable the Mediant 1000B PSTN gateway in the branch site:
Grounding the Device – see Chapter
Connecting to the LAN – see Chapter
Connecting to FXS interfaces – see Chapter
Connecting to BRI lines – see Chapter
Connecting to E1/T1 trunks – see Chapter
Connecting the PSTN Fallback for E1/T1 Trunks – see Chapter
Connecting to Power – see Chapter
6.1
Grounding the Device
The procedure below describes how to ground the device.
Protective Earthing
The equipment is classified as Class I EN 60950 and UL 60950 and must be earthed
at all times (using an equipment-earthing conductor).
•
Finland: "Laite on liltettava suojamaadoituskoskettimilla varustettuun pistorasiaan."
•
Norway: "Apparatet rna tilkoples jordet stikkontakt."
•
Sweden: "Apparaten skall anslutas till jordat uttag."
To ground the device:
1.
Connect an electrically earthed strap of 16 AWG wire (minimum) to the chassis'
earthing screw (located on the rear panel), using the supplied washer.
Figure
6-1: Grounding the Device
2.
Connect the other end of the strap to a protective earthing. This should be in
accordance with the regulations enforced in the country in which the device is
installed.
Summary of Contents for Mediant 1000B SBA
Page 2: ......
Page 22: ......
Page 38: ......
Page 54: ......
Page 70: ......
Page 142: ......
Page 191: ...Part VI Upgrading the SBA Components This part describes how to upgrade the SBA components...
Page 192: ......
Page 204: ......
Page 233: ...4 Part VIII Appendices...
Page 234: ......
Page 298: ...SBA Installation and Maintenance Manual www audiocodes com www audiocodes com...