background image

AUDIO INTERNATIONAL, INC. 

 

3/98 

 

10 

Document #540068, Rev. IR, Model No.: RCP-020-x & RCP-021-40x 

2.9.3  Load the cassette player with selected material.  Verify that the RCP 

automatically plays back the selected cassette.  Use the front panel 
controls or the hand-held remote control to select track search, play, pause, 
eject, etc.  Refer to operating instructions for the unit.   Verify that all 
functions are operational.  Verify that the RCP audio can be heard through 
the speaker and/or headphone system. 

 
3.0 Operation 
 

3.1 Audio 

Input 

 

 
Load the cassette player with selected material.  With the aircraft and audio power 
“ON”, apply power to the unit by turning the unit “ON” either by remote control 
or pressing play on the front panel.  Refer to operating instruction for the unit.  
 

3.2 Potentiometer 

Adjustment 

 

Verify that the selected material may be heard.  If applicable, adjust the output 
level gain adjustment potentiometers on the rear of the unit until the desired audio 
options have been obtained.  

 
3.3 Audio 

Adjustment 

 

To operate the AM/FM radio, apply power to the unit by turning the tuner power 
to the “ON” position.  Use AM/FM random search to select the desired radio 
station.  The station numbers will appear in the digital window as they are “tuned” 
in. 

 
3.4 Power 

Removal 

 

If a cassette is in the unit, and power is removed, the cassette must be ejected and 
reinserted to resume play once power is reapplied. 

 

4.0 Troubleshooting   

 

 
 Problem Possible 

Cause 

Solution 

 

No sound 

RCP is improperly installed  
 
 
No audio material in source unit. 
 
 

Verify 28 VDC power and audio  
output is present  
 
Insert audio material in source 
unit 
 
 

 

Poor audio quality 

Audio controls are not adjusted 
properly. 

Adjust output level. 

 

Poor Tuner reception 

Antenna connection may be 
faulty 

Verify antenna connections 

 

Summary of Contents for RCP-020-x

Page 1: ...r L 7300 Industry Drive North Little Rock AR 72117 Phone 501 955 2929 Fax 501 955 2988 Product Installation Manual Cassette Player AM FM Tuner Model No s RCP 020 x 40x RCP 021 40x Document 540068 ...

Page 2: ...020 x RCP 021 40x Revision History Rev Level Date Description IR 3 98 Initial Release Applicable Documents Document Drawing Description N A 521129 RCP 020 x 40x Cassette Player AM FM Tuner N A 521873 RCP 021 40x Cassette Player AM FM Tuner 560023 N A Operation s Guide ...

Page 3: ...TERNATIONAL INC 3 98 3 Document 540068 Rev IR Model No RCP 020 x RCP 021 40x Service Bulletin List Service Bulletin Subject Manual Revision Manual Revision Date List of Illustrations Section No Description Page ...

Page 4: ...nnections 8 2 7 Pinouts Descriptions 8 2 8 Connector Mating Connector Information 9 2 9 Post Installation Test 9 3 0 Operation 10 3 1 Audio Input 10 3 2 Potentiometer Adjustment 10 3 3 Audio Adjustment 10 3 4 Power Removal 10 4 0 Troubleshooting 10 5 0 Specifications and Drawings 11 5 1 Unit Specifications 11 5 2 Applicable Drawings 11 PROPRIETARY NOTICE Despite any copyright notice this data and ...

Page 5: ...nclude track search track repeat track scan and random play mode The unit has high quality output adjustable stereo output level from 1 to 5 volts RMS and full range frequency response of 20Hz to 20kHz 1dB The cassette tape player can be mounted in a cabinet or in a bulkhead AI source equipment can be optionally controlled by infrared remote A unique strapping feature allows up to four 4 similar d...

Page 6: ...ng conditions as to the unit location and type of installation The following should be carefully considered before installing 2 1 1 Select a mounting location for the unit where 28 VDC power and audio signal has been previously installed Long low level runs may introduce noise into the audio signal Refer to Section 5 0 Specifications and Drawings for location of mounting points 2 1 2 Locate the un...

Page 7: ...he length and routing of external cables must be carefully studied and planned before attempting installation of the equipment Allow adequate space for installation of cable and connectors Avoid sharp bends and placing cables near aircraft control cables Maintain a minimum clearance of three 3 inches from any control cable If wiring is run parallel to combustible fluid or oxygen lines maintain a s...

Page 8: ...frared digital command codes and 12 VDC battery holdup The flying lead BNC connector provides antenna high and antenna shield connections 2 6 3 Standard configuration requires no infrared strap pins to be connected Each different type of AI source equipment can be configured to accept one of four 4 different sets of infrared codes To change the code settings connect one 1 of the strap pins to the ...

Page 9: ...P 020 RCP 020 402 CBD21WIM CBD21WIF D20418 2 Female Screw Lock D20419 18 Male Screw RCP 020 1 RCP 020 401 CBD21WIM CBD21WIF D9 370000V30 Locking Tab RCP 021 401 RD15M10JV30 RD15F10JVL0 RCP 021 402 DAMA 15P DAMA 15S D20418 2 Female Screw Lock D20419 18 Male Screw Antenna BNC Amphenol 413779 4 or equivalent 2 9 Post Installation Test 2 9 1 The audio signal output of the unit is generally connected t...

Page 10: ...justment Verify that the selected material may be heard If applicable adjust the output level gain adjustment potentiometers on the rear of the unit until the desired audio options have been obtained 3 3 Audio Adjustment To operate the AM FM radio apply power to the unit by turning the tuner power to the ON position Use AM FM random search to select the desired radio station The station numbers wi...

Page 11: ...m sec Wow Flutter WRMS 0 08 Frequency Response 30 Hz to 18 kHz 3 dB Separation 1 kHz 43 dB Signal to Noise Ratio 54 dB Dolby B NR Off 63 dB Dolby B NR On FM Tuner Specifications Frequency Range 87 9 MHz 107 9 MHz Channel Space 200 kHz Usable Sensitivity S N 30dB 9 3 dBf 0 8 µ V 75 ohms Frequency Response 30 Hz to 15 kHz 3 dB Signal to Noise Ratio 75 dB MONO Stereo Separation 40 dB 1 kHz AM Tuner S...

Page 12: ...odel No RCP 020 x RCP 021 40x 5 2 2 The following diagram shows the top view of the RCP with unit dimensions 5 2 2 The following is a reduced diagram showing the side and rear views of the RCP 020 x 40x unit showing the ball stud location and unit dimensions ...

Page 13: ...NAL INC 3 98 13 Document 540068 Rev IR Model No RCP 020 x RCP 021 40x 5 2 3 The following is a reduced diagram showing the side and rear views of the RCP 021 40x unit showing the ball stud location and unit dimensions ...

Reviews: