![Audio Authority 1341R User Manual Download Page 5](http://html1.mh-extra.com/html/audio-authority/1341r/1341r_user-manual_3007988005.webp)
5
3.0 SYSTEM DESIGN
Consider the following factors and basic precautions to ensure the best possible
performance.
• Do not use soldered BNC connectors or adapters.
RG-6 cables
MUST
be
terminated with either crimp-on or compression type BNC connectors.
• Use high quality RG-6 coaxial cable.
The HXE-11 can transmit HD video
over a single coax cable using high quality RG-6 and terminating with good
crimp-on BNC connectors. Low quality cable and RG-59 cable does not
provide the bandwidth necessary for the HXE-11 system.
•
Do not use HD-DVD players.
The HDCP keys in the 1341T do not support
Legacy HD-DVD players and will not handshake or pass signals.
•
Source and TV connection cables.
Use short, premium HDMI cables; low
quality cables are often unreliable. Always use good strain relief methods or
locking cables to prevent cables from becoming loose over time.
•
Interference from nearby electrical devices
can have an adverse effect
on signal quality. For example, older computer monitors often emit very high
electromagnetic fields that can interfere with the performance of nearby video
equipment.
•
Display devices.
The perceived quality of the video image depends heavily
upon the type and quality of the TVs or projectors used. High quality displays
should be expected to produce a noticeably better image.
SOURCE
HDTV
1341T
1341R
RG-6 CABLE
HDMI
CABLE
3.1 APPLICATIONS
The 1341T and 1341R may be used in simple point-to-point applications or in
multiple destination video distribution applications.
Point-to-point Extension Application
TERMINATE LAST