background image

22

For proper functioning of the hearing aid, make sure the Wax Guard remains 
clean and un-obstructed by using the enclosed brush.

You will occasionally have to change the Wax Guard when the hearing 
instrument appears to be dead or weak.

Front View

Wax Guard

Side View

Wax Guard System

Summary of Contents for Uno

Page 1: ...Instruction Manual Uno ...

Page 2: ...2 Thank you for choosing Audicus We are excited for you to experience our hearing aids If you have any questions feel free to contact us at 888 979 6918 or help audicus com ...

Page 3: ...verview 7 Maintenance and Use 29 What s Inside 8 Returns and Warranty 32 Batteries 10 Technical Information 33 On Off 15 FDA Information 34 Wearing the Hearing Aid 16 Warnings and Side Effects 37 Domes 19 Contact Us 38 Cleaning 22 Contents ...

Page 4: ...quality 3 Auto adapts to all listening environments 4 Has speech filtration 5 Has feedback and noise reduction The Uno is equipped with one memory program customized to your hearing loss The Uno is practically invisible as it sits deep in the ear canal It provides excellent sound quality and it is comfortable to wear all day long ...

Page 5: ...5 Overview Uno Battery Compartment Extension Cord Serial Number Left Right Extraction cord Sound Nozzle Dome ...

Page 6: ...6 Clam Shell Closed Uno Clam Shell Opened Hearing Aid Domes What s Inside ...

Page 7: ...7 What s Inside Manual Earwax Guard Wheel and Insertion tool Size 10 Batteries Cleaning Brush Instruction Manual Uno Magnetic end for extracting batteries ...

Page 8: ...8 Inserting the Battery The Uno uses size 10 zinc batteries 1 Place the battery into the battery compartment with the sticker facing up Batteries ...

Page 9: ...9 Batteries Inserting the Battery 2 Peel the sticker off the new battery The sign should be visible on the battery This activates the battery 1 2 3 ...

Page 10: ...our device e g when you go to sleep we recommend opening the battery compartment completely to preserve battery power Leaking batteries damage the system Please remove batteries when the hearing systems are not in use for a prolonged period of time Low Battery Warning When your battery runs low the device will emit continuous beeps Batteries ...

Page 11: ...11 Removing the Battery To remove the battery gently open the battery door with your fingernail Remove the old battery You may use the magnetic end of the Cleaning Brush to extract the battery Batteries ...

Page 12: ...s according to federal and local regulations Never attempt to recharge batteries that are not rechargeable as this could result in an explosion Keep batteries away from sources of high temperature Keep batteries away from children and pets Do not carry batteries loose in your pocket or purse Do not place batteries in your mouth if swallowed consult a physician ...

Page 13: ...or OFF through its battery compartment When the battery door is closed the device is switched ON When the battery door is fully open the device is OFF When the device is not in use we recommend opening the battery compartment in order to preserve battery power Off On ...

Page 14: ...al number should face in the direction of the front of your face Wearing the Hearing Aid 1 Red Right Ear Blue Left Ear Red Right Ear Blue Left Ear 2 Position the tip of the hearing aid into your ear canal 3 Push the tip upwards and into your ear canal The extraction cord should press against your earbowl ...

Page 15: ...15 Wearing the Hearing Aid 2 3 If you have trouble inserting the hearing aid please contact us at 888 979 6918 for assistance ...

Page 16: ...sier by gently pulling the bottom of the ear down Considerations Handle your hearing aid with care when placing it in your ear If it does not feel comfortable do not attempt to alter the shape of the hearing aid Do not use broken domes If a dome becomes lodged in your ear contact a medical professional for removal If you feel physical discomfort or experience irritation contact Audicus and or a he...

Page 17: ...n request A medium sized mushroom dome is already installed on the hearing aid when you receive it If after properly inserting the aid in your ear you experience whistling feedback then the dome is too loose and must be changed to a larger size If the medium dome is too big switch to a smaller one Domes S M and L Propeller Domes S M and L Mushroom Domes ...

Page 18: ...18 Domes To Remove the Domes After continued use the dome might wear out and need to be replaced At that time remove it by pulling it off and placing a new dome onto the device 1 2 ...

Page 19: ...19 Domes To Attach the Domes Make sure the dome is properly covering the sound nozzle 1 2 ...

Page 20: ...fe of the device Do not allow liquid to enter any openings on the instruments Inspect the sound nozzle portion of the hearing aid for any wax buildup and be careful not to push wax into the opening Remove earwax with the enclosed brush and consider using the Wax Guard System supplied Wipe using a Cloth Clean using the Brush ...

Page 21: ...21 Wax Guard System Your Uno hearing aid comes with a Wax Guard System for replacing the Wax Guard A B Left Right Wax Guard System Spiral End Plastic End Insertion Tool Wax Guard Wheel Insertion Tool ...

Page 22: ... aid make sure the Wax Guard remains clean and un obstructed by using the enclosed brush You will occasionally have to change the Wax Guard when the hearing instrument appears to be dead or weak Front View Wax Guard Side View Wax Guard System ...

Page 23: ...x Guard System 1 A To Remove the Wax Cover 1 Insert the spiral end A of the insertion tool into the used Wax Guard as shown in the illustration Screw the spiral end 6 times to fasten Used Wax Guard Side View ...

Page 24: ...24 2 To Remove the Wax Guard 2 Pull the used Wax Guard out of the hearing aid 3 Eject the used Wax Guard into the center of the Wax Guard Wheel 3 Wax Guard System ...

Page 25: ...25 Wax Guard System To Install a new Wax Guard 1 Remove new Wax Guard from the dial pack using the plastic end B of the insertion tool that is provided 1 B ...

Page 26: ...uard into the hearing aid end 3 Tilt the tool to leave the new Wax Guard inside the hearing aid end 4 Pull the insertion tool away from the hearing instrument leaving the new Wax Guard in place It should be flush with the canal tip 2 3 4 Wax Guard System ...

Page 27: ...le swimming Always keep the device protected when out in the rain If the device becomes wet remove the battery and ensure the device is dry before using it again Never subject your device to hairspray sunscreen aftershave perfume gel cream or other cosmetic medical products In areas of high humidity periodically remove the device and put it in a warm place to dry out Note Your hearing aid is sensi...

Page 28: ...not wear your hearing aid when using a hair dryer Do not leave your hearing aid exposed to direct sunlight for an extended period of time Storage Always remove the battery from the device when not in use for extended periods Always store your hearing aid in its case in a clean and dry environment Keep your hearing aid from children and pets Consider a dehumidifier for most effective storage ...

Page 29: ...hone however electromagnetic field effects cannot be ruled out Handle the device over a flat surface such as a table to avoid dropping it Do not alter or attempt any repairs on the device as it might void the warranty Do not place your hearing system in the microwave In some countries restrictions on the use of wireless equipment may apply consult local authorities for more information WARNING Cho...

Page 30: ...ranty All our hearing aids come with a full 12 month manufacturer guarantee that covers manufacturing defects The guarantee will not be valid if the devices have been modified or damaged by the user or if the serial number has been altered or if repairs have been made without the consent and knowledge of Audicus If your device stops functioning correctly and you believe you have a guarantee case p...

Page 31: ...31 Serial Identification Where to locate serial number You can find your serial number on the surface of the hearing aid The serial number is 7 digits long Serial Number ...

Page 32: ...hese limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation I...

Page 33: ...u are experiencing discomfort see your audiologist or hearing care professional immediately for modification of the hearing aid or earmold at the point of irritation A hearing aid or earmold may cause an accelerated accumulation of cerumen earwax Also in rare cases the otherwise nonallergenic material may cause a discharge from the ear allergic reaction or any other unusual condition Please seek i...

Page 34: ...e remaining hearing of the hearing aid user Information for U S users from the Federal Drug Administration Department of Health Edu cation and Welfare Rules and Regulations for Medical Devices part 801 Hearing Aid Devices Professional and Patient Labeling and Conditions for Sale Good health practice requires that a person with a hearing loss have a medical evaluation by a licensed physician prefer...

Page 35: ...hysician for a medical evaluation a child with hearing loss should be directed to an audiologist for evaluation and rehabilitation since hearing loss may cause problems in language development and the educational and social growth of a child An audiologist is qualified by training and experience to assist in the evaluation and rehabilitation of a child with hearing loss Identification Information ...

Page 36: ...ident of safe distance e g 4 in 10 cm of pacemaker Keep magnets away from children if swallowed seek medical attention immediately Magnets can disturb electrical devices and delete stored data Keep magnets away from computers color monitors television sets CD smartphone screens video and audio discs and other electronic equipment devices ...

Page 37: ...ve ear canal blockage a lasting ear infection or a plugged up fullness feeling Consult a licensed physician if you have ringing in one or both ears within last 90 days Keep hearing systems out of the reach of children pets and individuals with diminished mental capacity Hearing systems should be used only as directed and adjusted by your trained hearing system professional A hearing system may sto...

Page 38: ...38 Contact Us Audicus Inc 134 West 29th St 5th Fl New York NY 10001 Tel 888 979 6918 Email help audicus com www audicus com ...

Page 39: ...39 ...

Page 40: ......