background image

Page 2

Page 9

Installation

In order to use the product securely and properly, please read the 

manual before using and follow the instructions strictly to prevent 

personal safety trouble and product damage caused by misuse.

Take care of the product, check the possibility of the product damage 

caused by transportation and check all the listed items are present upon 

receipt of the product:

LED Spot Light 

 1 

  Use Manual 

 1

Power cable       1 

 Handle 

 2

1. Make sure there is no flammable or explosive subjects within min 1.5

meter nearby the installation, the distance between wall and the light 

shall be min 0.5M

2.Before installation, please check and make sure the power supply

voltage meet request of the system.

3. Please check ventilation and fans or exhaust passages are cleared.

4. The equipment should be fixed firmly.

5. For security reasons, the appliance must be earthed.

Inspection

1

2

3

4

5

6

7

Fault checking and repair)

No.

Fault description

Fault Checking

Not work,no light 

output and the 

fan doesn't work

1.Check power connection and see if the fuse is OK
2.Check if voltage value is in the normal range
3.Check power switch and disply screen  on or off

DMX no control

1.DMX signal light must be on, if not, to check the

connection
2. If DMX signal light is on, but no reaction to the

channel, to check if the address code setting is correct?
3.If DMX signal is discontinuous, please check if 

CANNON cable connect well?
4.Please Change to another DMX controller
5.Please Check if DMX signal cable is too close the 

high-tension busbar which will damage or interrput the 

signal output

One of channel 

blocked

1.Be sure no DMX signal received

2.Please Check sound control is on and sensitivity is on 

the right range

2.Driving circuit of motor might be damaged

Light sources work 

discontinuously

1.Please check if input voltage is too high or too low?
2.The inner temperature is probably too high, change 

a new fan if necessary

Can't be controlled 

by Sound

1.Be sure no DMX signal received

3.Please Check if mic is damaged
4.Please Check if the light is on "HOLD" situation.

Horizontal 

synchronous belt 

damaged

1.Power off
2.Unscrewing screws of outer case and open the base 

case
3.Unscrewing screws which are connect base case to 

nose-arm parts
4.Loose all of the connecting cables
5.Please change new synchronous belt and installed it 

on the gear shaft and the motor driving wheel 

(Attention: the belt can't be too tight in case broken
6.Please Connect all cables
7.Tighten all the screws
1. Switch off power

2.Unscrew screws of outer shell of arm parts and take 

off the outer case
3.Loose the screws of y-axis' motor driven board
4.Please Change to new synchronous belt 

(Attention: the belt can't be too tight in case broken)
5.Tighten all the screws

Vertical synchronous 

belt damaged