Connecting the speaker
For connecting the KYRA, the wires coming from the amplifier shall be connected to
the 3-pin terminal block connector on the rear of the speaker. Depending whether the
speaker will be used in a low impedance (12
Ω
) system or a constant voltage (70V/100V)
system, the appropriate terminals of the connector should get connected as indicated
in the below drawing.
COM
12 Ω
70V/
100V
A
D
B
C
When using in constant voltage 70V/100V systems, the power taps can be adjusted
in 4 steps of impedance through a rotary selector switch on the rear side of the unit.
The switch can be rotated in 4 positions A, B, C & D. Each position corresponds with
a specific impedance / power setting indicated on a label attached to the speaker, and
in the table below.
COM
12 Ω
70V/
100V
A
D
B
C
KYRA6
KYRA12
Tapping
100V
70V
Imp.
Tapping
100V
70V
Imp
A
Do not use
20 W
250
Ω
A
Do not use
40 W
125
Ω
B
20 W
10 W
500
Ω
B
40 W
20 W
250
Ω
C
10 W
5 W
1000
Ω
C
20 W
10 W
500
Ω
D
5 W
2.5 W
2000
Ω
D
10 W
5 W
1000
Ω