background image

  AUBER INSTRUMENTS

    

 

 

     

 

 

 

             

WWW.AUBERINS.COM  

 

2021.07                                                                                                                                                                                                         P1/3

 

DIN Rail Mounted Programmable Digital Timer Switch 

(TS-DR-110 / TS-DR-12)

   

Version 1.1 (Jul, 2021) 

 

1. Overview 

This is a programmable digital timer switch with relay output. It can be used to 
switch on or off lights, appliance, or other small loads at specified date and 
time. The timer can be programmed to turn on/off the relay in 17 different daily/ 
weekly schedules. Manual mode is available to overrule the programmed relay 
events. A 1.2 V / 40 mA lithium battery inside the timer switch provides power 
to the timer and it will be charged whenever the switch is connected to an AC 
power. The DIN rail mount of this timer switch makes it suitable for power 
management in a control panel.  
      

2. Specifications 

Table 1. Specifications 

Power supply voltage rating 

110 VAC or 12 V AC / DC 

Power consumption (MAX) 

2 W  

Display type 

LCD 

Relay lifetime 

Mechanically 10,000,000;  
Electrically: 100,000 

Load capacity 

Resistive load: 16 A / 250 V AC;  
Lagging load: 8 A / 250 V AC;  
Lamp Load: 2000 W 

Output relay 

1 x form C relay (1 N.O., 1 N.C.) 

Timer range 

1 minute ~ 168 hours (7 days) 

Timer deviation 

+/- 1 second / 24 hours, 25° C 

Power-off memory 

60 days 

Working temperature 

-14° F ~ 104° F ( -10° C ~ + 40° C) 

Ambient humidity 

35 - 85% RH 

Power reserve 

3 years (lithium battery) 

Size 

86.5 mm x 36 mm x 65.5 mm 

Weight 

120 g 

 

3. Dimensions 

 

Figure 1. Dimensions of TS-DR-110 / TS-DR-12.  

4. Wiring Diagrams 

 

Figure 2(a). Wiring for 110V AC version TS-DR-110. 

 

 

Figure 2(b). Wiring for 12V DC version TS-DR-12. 

 
 

Instruction Manual

 

 

Reviews: