Auber Instruments SYL-2615 Instruction Manual Download Page 7

         AUBER INSTRUMENTS

  

 

 

 

 

 

 

 

         

WWW.AUBERINS.COM  

 

 

         2019.07                                                                     

   

                                                       P7/7 

 

away from the heat from the smoker. Avoid exposing the controller under 
directly sunshine during hot summer. 
 

 

Figure 14. Two M4 screw holes on the back of the controller. 

 
 

8. FAQ 
8.1 Probe reading showing 

-H-

This is the sensor input error message. It appears when the sensor is not 
connected, sensor is bad or controller is bad. If you only see -H- error on one 
probe, you can swap two probes to the different sockets (for example, plug in 
pit probe to meat probe socket, and plug in meat probe to pit probe socket). If 
this issue remains on the probe, your probe is bad. If this issue remains on the 
controller, your controller is bad. For more details, please contact customer 
support.   

 

8.2 What if one step is set to end by food temperature while the food 
probe is not plugged in? 

If “

X-End

” of a certain step is set to “

Fd Temp

” while the food probe is not 

plugged in, this step will never end.  
 

(End) 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 

Auber Instruments Inc. 

5755 North Point Parkway, Suite 99, 

Alpharetta, GA 30022 

www.auberins.com 

E-mail: [email protected] Tel: 770-569-8420 

 

Copyright 2007-2019, Auber Instruments All Rights Reserved. 

No part of this manual shall be copied, reproduced, or transmitted in any way without 

the prior, written consent of Auber Instruments. Auber Instruments retains the exclusive 

rights to all information included in this document. 

 

Summary of Contents for SYL-2615

Page 1: ...of which the cooking time is unknown it is better to set a target food temperature to end the step SYL 2615 has a build in Wi Fi module which allows its user to monitor the temperature and control the...

Page 2: ...ut 99 SET Press and hold Figure 5 Access the menu of parameters using SET key 5 Getting Started Power on the controller by plugging the barrel connector from the 12 VDC adapter to the power input port...

Page 3: ...N A In this example a user set the pit temperature of Step 1 to 275 F which is higher than normal smoking temperature to speed up the low and slow cooking without compromising the moisture Step 1 wil...

Page 4: ...2 WSM18 4 5 6 Back 9 Recall Recall PID Settings Back BGE WSM22 WSM18 4 5 6 Back 9 Back Back to main menu Control config System config AH Pit 350 AL Pit 0 AL Pit 0 AH Food 350 Back AH Pit 250 SET SET A...

Page 5: ...he rate of change rather than the net amount of change This will allow the controller to act sooner It will turn the heater to full power before the temperature drops too much Note 7 T Control Cycle T...

Page 6: ...manually adjust the fan speed output voltage Note 12 FMRV Fan minimum running voltage This parameter is only used when controller is running under fan speed control mode Due to the variation in the fr...

Page 7: ...on the probe your probe is bad If this issue remains on the controller your controller is bad For more details please contact customer support 8 2 What if one step is set to end by food temperature w...

Reviews: